Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials

© 2020, © 2020 Informa UK Limited, trading as Taylor & Francis Group. The dichlorophenol-indophenol (DCIP) test and microcolumn chromatography are simple methods commonly used for screening of Hb E (HBB: c.79G>A) in Thailand. However, there is no proficiency testing (PT) program for these s...

Full description

Saved in:
Bibliographic Details
Main Authors: Sakorn Pornprasert, Sirithorn Surajinda, Panida Pongpunyayuen, Manoo Punyamung, Chedtapak Ruengdit, Nutjeera Intasai
Format: Journal
Published: 2020
Subjects:
Online Access:https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086050092&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70252
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Chiang Mai University
id th-cmuir.6653943832-70252
record_format dspace
spelling th-cmuir.6653943832-702522020-10-14T08:43:20Z Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials Sakorn Pornprasert Sirithorn Surajinda Panida Pongpunyayuen Manoo Punyamung Chedtapak Ruengdit Nutjeera Intasai Biochemistry, Genetics and Molecular Biology Medicine © 2020, © 2020 Informa UK Limited, trading as Taylor & Francis Group. The dichlorophenol-indophenol (DCIP) test and microcolumn chromatography are simple methods commonly used for screening of Hb E (HBB: c.79G>A) in Thailand. However, there is no proficiency testing (PT) program for these screening tests. Thus, the aim of this study was to evaluate an efficiency of lyophilized hemoglobin (Hb) control materials used in the established PT program for Hb E screening at the Associated Medical Sciences-Clinical Service Center (AMS-CSC), Chiang Mai University, Chiang Mai, Thailand. Three cycles of PT were performed from June 2018 to July 2019. In each cycle, five different types of control materials were provided to the participants. Each participant analyzed the control materials in the same manner as in their routine practices for Hb E screening. The results showed that the number of participants increased from 95 in the first cycle to 126 and 134 in the second and third cycles, respectively. The numbers of participants who used the DCIP screening test and reported the result correctly increased from 79 (85.87%) to 106 (89.08%) and 112 (89.60%), respectively. Whereas those who used the microcolumn chromatography method and reported correct results were decreased from 100.0 to 85.71 and 66.67%, respectively. Thus, lyophilized Hb, control materials can be used effectively for the PT program of Hb E screening test. However, the further improvement, especially in skills of Hb E analysis by microcolumn chromatography, is required for some participating laboratories. 2020-10-14T08:26:15Z 2020-10-14T08:26:15Z 2020-03-03 Journal 1532432X 03630269 2-s2.0-85086050092 10.1080/03630269.2020.1734612 https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086050092&origin=inward http://cmuir.cmu.ac.th/jspui/handle/6653943832/70252
institution Chiang Mai University
building Chiang Mai University Library
continent Asia
country Thailand
Thailand
content_provider Chiang Mai University Library
collection CMU Intellectual Repository
topic Biochemistry, Genetics and Molecular Biology
Medicine
spellingShingle Biochemistry, Genetics and Molecular Biology
Medicine
Sakorn Pornprasert
Sirithorn Surajinda
Panida Pongpunyayuen
Manoo Punyamung
Chedtapak Ruengdit
Nutjeera Intasai
Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
description © 2020, © 2020 Informa UK Limited, trading as Taylor & Francis Group. The dichlorophenol-indophenol (DCIP) test and microcolumn chromatography are simple methods commonly used for screening of Hb E (HBB: c.79G>A) in Thailand. However, there is no proficiency testing (PT) program for these screening tests. Thus, the aim of this study was to evaluate an efficiency of lyophilized hemoglobin (Hb) control materials used in the established PT program for Hb E screening at the Associated Medical Sciences-Clinical Service Center (AMS-CSC), Chiang Mai University, Chiang Mai, Thailand. Three cycles of PT were performed from June 2018 to July 2019. In each cycle, five different types of control materials were provided to the participants. Each participant analyzed the control materials in the same manner as in their routine practices for Hb E screening. The results showed that the number of participants increased from 95 in the first cycle to 126 and 134 in the second and third cycles, respectively. The numbers of participants who used the DCIP screening test and reported the result correctly increased from 79 (85.87%) to 106 (89.08%) and 112 (89.60%), respectively. Whereas those who used the microcolumn chromatography method and reported correct results were decreased from 100.0 to 85.71 and 66.67%, respectively. Thus, lyophilized Hb, control materials can be used effectively for the PT program of Hb E screening test. However, the further improvement, especially in skills of Hb E analysis by microcolumn chromatography, is required for some participating laboratories.
format Journal
author Sakorn Pornprasert
Sirithorn Surajinda
Panida Pongpunyayuen
Manoo Punyamung
Chedtapak Ruengdit
Nutjeera Intasai
author_facet Sakorn Pornprasert
Sirithorn Surajinda
Panida Pongpunyayuen
Manoo Punyamung
Chedtapak Ruengdit
Nutjeera Intasai
author_sort Sakorn Pornprasert
title Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
title_short Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
title_full Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
title_fullStr Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
title_full_unstemmed Proficiency Testing Program for Hb E (HBB: c.79G>A) Screening in Thailand Using Lyophilized Hb E Control Materials
title_sort proficiency testing program for hb e (hbb: c.79g>a) screening in thailand using lyophilized hb e control materials
publishDate 2020
url https://www.scopus.com/inward/record.uri?partnerID=HzOxMe3b&scp=85086050092&origin=inward
http://cmuir.cmu.ac.th/jspui/handle/6653943832/70252
_version_ 1681752868937269248