Recently, Gas Insulated Switchgear (GIS) is widely used in electrical system. This is due to the fact that GIS has many advantages compared with other types of switchgear, like more efficient space for installation and better protection from pollution. However, GIS is still vulnerable to operation m...

Full description

Saved in:
Bibliographic Details
Main Author: PERMANA (NIM 13204064), CAESARIO
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/10116
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:10116
spelling id-itb.:101162017-09-27T10:18:44Z#TITLE_ALTERNATIVE# PERMANA (NIM 13204064), CAESARIO Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/10116 Recently, Gas Insulated Switchgear (GIS) is widely used in electrical system. This is due to the fact that GIS has many advantages compared with other types of switchgear, like more efficient space for installation and better protection from pollution. However, GIS is still vulnerable to operation malfunction and even breakdown caused by defects within it.<p> <br /> <br /> <br /> One of the methods to assess GIS insulation condition is by diagnosing partial discharges that occur within GIS which caused by the aforementioned defect.This final project reports the presence of partial discharges in the GIS compartments which have decomposition level above CIGR standard of 1000 ppm using acoustic emission method. Based on the PD measurement result, insulation condition of GIS was investigated. This diagnosis were done in Gunung Salak Substation.<p> <br /> <br /> <br /> From this research it is known that possible source of defect within GIS such as protrusion, free particle, or loose shields, can be detected using acoustic emission method. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Recently, Gas Insulated Switchgear (GIS) is widely used in electrical system. This is due to the fact that GIS has many advantages compared with other types of switchgear, like more efficient space for installation and better protection from pollution. However, GIS is still vulnerable to operation malfunction and even breakdown caused by defects within it.<p> <br /> <br /> <br /> One of the methods to assess GIS insulation condition is by diagnosing partial discharges that occur within GIS which caused by the aforementioned defect.This final project reports the presence of partial discharges in the GIS compartments which have decomposition level above CIGR standard of 1000 ppm using acoustic emission method. Based on the PD measurement result, insulation condition of GIS was investigated. This diagnosis were done in Gunung Salak Substation.<p> <br /> <br /> <br /> From this research it is known that possible source of defect within GIS such as protrusion, free particle, or loose shields, can be detected using acoustic emission method.
format Final Project
author PERMANA (NIM 13204064), CAESARIO
spellingShingle PERMANA (NIM 13204064), CAESARIO
#TITLE_ALTERNATIVE#
author_facet PERMANA (NIM 13204064), CAESARIO
author_sort PERMANA (NIM 13204064), CAESARIO
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/10116
_version_ 1820664885763112960