Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)

<p align="justify">Theoretically, Extra High Voltage (EHV) 500 kV transmission lines are more robust against lightning strikes than EHV 150 kV or 70 kV. However, in case of EHV 500 kV Paiton-Kediri in Java, after five-years operation, many insulators were broken by lightning strikes,...

Full description

Saved in:
Bibliographic Details
Main Author: YUDO PRAMONO (NIM 23205024), EKO
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/10330
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:10330
spelling id-itb.:103302017-09-27T15:37:36ZEvaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission) YUDO PRAMONO (NIM 23205024), EKO Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/10330 <p align="justify">Theoretically, Extra High Voltage (EHV) 500 kV transmission lines are more robust against lightning strikes than EHV 150 kV or 70 kV. However, in case of EHV 500 kV Paiton-Kediri in Java, after five-years operation, many insulators were broken by lightning strikes, especially during rainy season. A large number of broken insulator deterioted performance of the lines, in which many line outages occurred.<p align="justify"><p>Based on that research must be done to get corresponding lightning performance of the line with involved the lightning characteristic of an area where the transmission passed, in order to calculated the lightning performance of 500 kV EHV Paiton-Kediri and to determine the tower which must be improve to fulfil performance of 500 kV EHV transmission that want by PT. PLN P3B Java Bali.<p align="justify"><p>The severity index method could be applied to determine the critical spots along that transmission line so we can know which tower will be improve according with an economically reason.<p align="justify"><p>The calculation of that index based on an historical lightning incidence in narrow strip along the line, and from evaluation of severity of lightning stress over the tower insulators for each tower along the line, with involved the tower parameters like tower height, tower altitude and tower footing resistance. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <p align="justify">Theoretically, Extra High Voltage (EHV) 500 kV transmission lines are more robust against lightning strikes than EHV 150 kV or 70 kV. However, in case of EHV 500 kV Paiton-Kediri in Java, after five-years operation, many insulators were broken by lightning strikes, especially during rainy season. A large number of broken insulator deterioted performance of the lines, in which many line outages occurred.<p align="justify"><p>Based on that research must be done to get corresponding lightning performance of the line with involved the lightning characteristic of an area where the transmission passed, in order to calculated the lightning performance of 500 kV EHV Paiton-Kediri and to determine the tower which must be improve to fulfil performance of 500 kV EHV transmission that want by PT. PLN P3B Java Bali.<p align="justify"><p>The severity index method could be applied to determine the critical spots along that transmission line so we can know which tower will be improve according with an economically reason.<p align="justify"><p>The calculation of that index based on an historical lightning incidence in narrow strip along the line, and from evaluation of severity of lightning stress over the tower insulators for each tower along the line, with involved the tower parameters like tower height, tower altitude and tower footing resistance. <br />
format Theses
author YUDO PRAMONO (NIM 23205024), EKO
spellingShingle YUDO PRAMONO (NIM 23205024), EKO
Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
author_facet YUDO PRAMONO (NIM 23205024), EKO
author_sort YUDO PRAMONO (NIM 23205024), EKO
title Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
title_short Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
title_full Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
title_fullStr Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
title_full_unstemmed Evaluation Of Lightning Performance 500 kV Extra High Voltage Transmission And Determination Of Critical Spots By Using Severity Index Method (Case Study on Paiton-Kediri 500 kV EHV Transmission)
title_sort evaluation of lightning performance 500 kv extra high voltage transmission and determination of critical spots by using severity index method (case study on paiton-kediri 500 kv ehv transmission)
url https://digilib.itb.ac.id/gdl/view/10330
_version_ 1820664944135241728