Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization

SUTET tower is Tower which sustaining cable to distribute the electrics from generating to consumer. This tower made from steel becouse it's strength and toughness. However, this steel is prone to the process corrosion to eliminate the nature of mechanic from the steel. Degradation of galvanis...

Full description

Saved in:
Bibliographic Details
Main Author: KARDI SARAGIH (NIM 12104020), KOPDI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/10780
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:10780
spelling id-itb.:107802017-09-27T10:37:14ZDegradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization KARDI SARAGIH (NIM 12104020), KOPDI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/10780 SUTET tower is Tower which sustaining cable to distribute the electrics from generating to consumer. This tower made from steel becouse it's strength and toughness. However, this steel is prone to the process corrosion to eliminate the nature of mechanic from the steel. Degradation of galvanis coat bressing steal calculated by using heavy loss method which converted to thick loss method of coat from coat of galvanisation Zn. Degradation of galvanis coat bressing steal got by compare thick loss of coat of galvanisation Zn with the age of wear. In this case, old of wear the tower SUTET is 23 Year. SUTET tower becoming research object is tower sutet of exist in various area by various condition of atmosphere environment which vary, like environment irrigate the sea, mountain, Industrial. From calculation result known that accelerateing corrosion is difference to each area and most of all from tower SUTET still except to useworthy except tower k 9.4, Gunung Salak-Bogor baru stripe. The highest accelerate of degradation reside in salty area equal to 5.73umpy. Galvanic Coat of Zn which remained at this SUTET tower only ready to protect the steel bressing for a few year to the fore. Bressing steal which is weared was Galvanization return with the its base metal consideration not yet corrosion and the thrift. Galvanization of bressing steal done in pure discharge Zn without element additional like aluminium, silicon and also nickel. Growth rate of galvanic Coat was coming near with the parabolik equation. Each steel have the unit growth rate of galvanic coat. By this, can be gained time correct to get thick of wanted coat. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description SUTET tower is Tower which sustaining cable to distribute the electrics from generating to consumer. This tower made from steel becouse it's strength and toughness. However, this steel is prone to the process corrosion to eliminate the nature of mechanic from the steel. Degradation of galvanis coat bressing steal calculated by using heavy loss method which converted to thick loss method of coat from coat of galvanisation Zn. Degradation of galvanis coat bressing steal got by compare thick loss of coat of galvanisation Zn with the age of wear. In this case, old of wear the tower SUTET is 23 Year. SUTET tower becoming research object is tower sutet of exist in various area by various condition of atmosphere environment which vary, like environment irrigate the sea, mountain, Industrial. From calculation result known that accelerateing corrosion is difference to each area and most of all from tower SUTET still except to useworthy except tower k 9.4, Gunung Salak-Bogor baru stripe. The highest accelerate of degradation reside in salty area equal to 5.73umpy. Galvanic Coat of Zn which remained at this SUTET tower only ready to protect the steel bressing for a few year to the fore. Bressing steal which is weared was Galvanization return with the its base metal consideration not yet corrosion and the thrift. Galvanization of bressing steal done in pure discharge Zn without element additional like aluminium, silicon and also nickel. Growth rate of galvanic Coat was coming near with the parabolik equation. Each steel have the unit growth rate of galvanic coat. By this, can be gained time correct to get thick of wanted coat.
format Final Project
author KARDI SARAGIH (NIM 12104020), KOPDI
spellingShingle KARDI SARAGIH (NIM 12104020), KOPDI
Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
author_facet KARDI SARAGIH (NIM 12104020), KOPDI
author_sort KARDI SARAGIH (NIM 12104020), KOPDI
title Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
title_short Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
title_full Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
title_fullStr Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
title_full_unstemmed Degradation of galvanis coat bressing steal at SUTET tower in West Java because of corrosion and Possibility for the regalvanization
title_sort degradation of galvanis coat bressing steal at sutet tower in west java because of corrosion and possibility for the regalvanization
url https://digilib.itb.ac.id/gdl/view/10780
_version_ 1822916922548682752