Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)

The analytical methods are generally high-cost, time and chemicals consuming. The usage of these chemicals makes the laboratory becomes the source of environmental pollutions. Flow Injection Analysis (FIA) method is a solution for reducing the high usage of chemicals since its measurement is less ti...

Full description

Saved in:
Bibliographic Details
Main Author: RIPTONO (NIM 10504034), AGUS
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/11749
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:11749
spelling id-itb.:117492017-09-27T11:42:35ZPreliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA) RIPTONO (NIM 10504034), AGUS Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/11749 The analytical methods are generally high-cost, time and chemicals consuming. The usage of these chemicals makes the laboratory becomes the source of environmental pollutions. Flow Injection Analysis (FIA) method is a solution for reducing the high usage of chemicals since its measurement is less time consuming and it does not need to reach the real system equilibrium. An analysis protocol for sulfate ion using one drop FIA method with spectrophotometric detection technique using optical fiber equipment was developed and evaluated. The evaluation results in a high analytical performance of the method, shown by the reproducibility values of 7.14% and 1.96% for concentration of 25 ppm and 125 ppm, respectively. Calibration curve showed a good linearity at the concentration range of 25 to 125 ppm with the approximate correlation value of 1. This method was applied to analyze the sulfate ion concentration in water from Jatiluhur dam. <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The analytical methods are generally high-cost, time and chemicals consuming. The usage of these chemicals makes the laboratory becomes the source of environmental pollutions. Flow Injection Analysis (FIA) method is a solution for reducing the high usage of chemicals since its measurement is less time consuming and it does not need to reach the real system equilibrium. An analysis protocol for sulfate ion using one drop FIA method with spectrophotometric detection technique using optical fiber equipment was developed and evaluated. The evaluation results in a high analytical performance of the method, shown by the reproducibility values of 7.14% and 1.96% for concentration of 25 ppm and 125 ppm, respectively. Calibration curve showed a good linearity at the concentration range of 25 to 125 ppm with the approximate correlation value of 1. This method was applied to analyze the sulfate ion concentration in water from Jatiluhur dam. <br />
format Final Project
author RIPTONO (NIM 10504034), AGUS
spellingShingle RIPTONO (NIM 10504034), AGUS
Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
author_facet RIPTONO (NIM 10504034), AGUS
author_sort RIPTONO (NIM 10504034), AGUS
title Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
title_short Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
title_full Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
title_fullStr Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
title_full_unstemmed Preliminary study of sulphate ion analysis method development based on One Drop Flow Injection Analysis (od-FIA)
title_sort preliminary study of sulphate ion analysis method development based on one drop flow injection analysis (od-fia)