#TITLE_ALTERNATIVE#

The application of strain gauge in determining strain value at one particular example of test to own the accuracy which is better than the application of dial gauge. But the application of strain gauge can only just used once so that costlier relative to use it. The application of measurement plate...

Full description

Saved in:
Bibliographic Details
Main Author: HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/11807
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:11807
spelling id-itb.:118072017-09-27T10:39:03Z#TITLE_ALTERNATIVE# HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/11807 The application of strain gauge in determining strain value at one particular example of test to own the accuracy which is better than the application of dial gauge. But the application of strain gauge can only just used once so that costlier relative to use it. The application of measurement plate makes the application of strain gauge can be used multiply. This measurement plate can be used to determine the axial strain in UCS test. But before the measurement plate can be aplicated to determining axial strain, it must have to being calibrated. So that the relation between strain of the measurement plate and the sample's strain can be determined.<p> <br /> <br /> <br /> <br /> <br /> The determination of relation between measurement plate's strain and the strain of sample has been conducted at axial direction. And then, the axial strain that happened at measurement plate by using strain gauge is calibrated to <br /> <br /> <br /> <br /> <br /> sample's axial strain. So that obtained a curve calibrate between strain of dial gauge with the strain of strain gauge at same encumbering condition.<p> <br /> <br /> <br /> <br /> <br /> The result of curve calibrate obtained by pursuant to examination is : <br /> <br /> <br /> <br /> <br /> Test Calibrate equation <br /> <br /> <br /> <br /> <br /> I y1 = 29,09x - 6E-07 <br /> <br /> <br /> <br /> <br /> II y2 = 29,9x - 1E-05 <br /> <br /> <br /> <br /> <br /> III y3 = 31,6x - 1E-05 <br /> <br /> <br /> <br /> <br /> IV y4 = 31,5x - 1E-05 <br /> <br /> <br /> <br /> <br /> V y5 = 31,6x - 1E-05 <br /> <br /> <br /> <br /> <br /> VI y6 = 33,4x - 6E-05 <br /> <br /> <br /> <br /> <br /> VII y7 = 31.4x + 3E-06 <br /> <br /> <br /> <br /> <br /> VIII Y8 = 32.8x - 6E-06 <br /> <br /> <br /> <br /> <br /> Where : <br /> <br /> <br /> <br /> <br /> x = dial gauge's strain <br /> <br /> <br /> <br /> <br /> y = strain gauge's strain <br /> <br /> <br /> <br /> <br /> Keywords : dial gauge, strain gauge, calibration. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The application of strain gauge in determining strain value at one particular example of test to own the accuracy which is better than the application of dial gauge. But the application of strain gauge can only just used once so that costlier relative to use it. The application of measurement plate makes the application of strain gauge can be used multiply. This measurement plate can be used to determine the axial strain in UCS test. But before the measurement plate can be aplicated to determining axial strain, it must have to being calibrated. So that the relation between strain of the measurement plate and the sample's strain can be determined.<p> <br /> <br /> <br /> <br /> <br /> The determination of relation between measurement plate's strain and the strain of sample has been conducted at axial direction. And then, the axial strain that happened at measurement plate by using strain gauge is calibrated to <br /> <br /> <br /> <br /> <br /> sample's axial strain. So that obtained a curve calibrate between strain of dial gauge with the strain of strain gauge at same encumbering condition.<p> <br /> <br /> <br /> <br /> <br /> The result of curve calibrate obtained by pursuant to examination is : <br /> <br /> <br /> <br /> <br /> Test Calibrate equation <br /> <br /> <br /> <br /> <br /> I y1 = 29,09x - 6E-07 <br /> <br /> <br /> <br /> <br /> II y2 = 29,9x - 1E-05 <br /> <br /> <br /> <br /> <br /> III y3 = 31,6x - 1E-05 <br /> <br /> <br /> <br /> <br /> IV y4 = 31,5x - 1E-05 <br /> <br /> <br /> <br /> <br /> V y5 = 31,6x - 1E-05 <br /> <br /> <br /> <br /> <br /> VI y6 = 33,4x - 6E-05 <br /> <br /> <br /> <br /> <br /> VII y7 = 31.4x + 3E-06 <br /> <br /> <br /> <br /> <br /> VIII Y8 = 32.8x - 6E-06 <br /> <br /> <br /> <br /> <br /> Where : <br /> <br /> <br /> <br /> <br /> x = dial gauge's strain <br /> <br /> <br /> <br /> <br /> y = strain gauge's strain <br /> <br /> <br /> <br /> <br /> Keywords : dial gauge, strain gauge, calibration.
format Final Project
author HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW
spellingShingle HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW
#TITLE_ALTERNATIVE#
author_facet HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW
author_sort HASOLOAN SITUMORANG (NIM 121 04 063), ANDREW
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/11807
_version_ 1820728319447924736