PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)

Mercury is one of the most toxic heavy metal and one of the sources of pollutant for our environment. The existences of mercury can come from human activities, such as industrial waste. The toxicity of mercury increases drastically on transformation to its organic forms, such as methyl mercury via b...

Full description

Saved in:
Bibliographic Details
Main Author: NASRA , EDI
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/12032
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:12032
spelling id-itb.:120322017-09-27T15:39:44ZPRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA) NASRA , EDI Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12032 Mercury is one of the most toxic heavy metal and one of the sources of pollutant for our environment. The existences of mercury can come from human activities, such as industrial waste. The toxicity of mercury increases drastically on transformation to its organic forms, such as methyl mercury via biomethylation through bacterial intervention in the environment. Mercury released into the atmosphere by a variety of natural and anthropogenic sources and can be easly enter human body through respiratory system or food. The accumulation of mercury on human body can cause so many dangerous impact such as cancer, reproduction gland disfunction, brain damage, osteophorosis, and nervous system poissoning. Therefore, the simple and effective analytical methods for determination of mercury are needed. Many experiments on mercury analysis have been reported, such as cold vapour atomic absorption CV-AAS, inductively coupled plasma mass spectrometry ICP-MS and several chromatographic techniques modificated with spectrometric methods. But yet, those methods have a complicated pretreatment and a highly cost. To increase the analitical sensitivity, some preconcentration methods, such as using solid phase extraction, hava been used to combine with AAS, AFS, ICP-MS or UV Visible Spectrometer based on Flow Injection Analysis (FIA) were effective for analysis of mercury. This method can be used for determination of very low concentration of mercury with a detection limit at part per billion level. The flow injection technique has such merits as a small volume of waste, which enhances the sensitivity of the methods and allows easy connection with an automated system. Preconcentration is a method to increase an analyte concentration without standard addition. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Mercury is one of the most toxic heavy metal and one of the sources of pollutant for our environment. The existences of mercury can come from human activities, such as industrial waste. The toxicity of mercury increases drastically on transformation to its organic forms, such as methyl mercury via biomethylation through bacterial intervention in the environment. Mercury released into the atmosphere by a variety of natural and anthropogenic sources and can be easly enter human body through respiratory system or food. The accumulation of mercury on human body can cause so many dangerous impact such as cancer, reproduction gland disfunction, brain damage, osteophorosis, and nervous system poissoning. Therefore, the simple and effective analytical methods for determination of mercury are needed. Many experiments on mercury analysis have been reported, such as cold vapour atomic absorption CV-AAS, inductively coupled plasma mass spectrometry ICP-MS and several chromatographic techniques modificated with spectrometric methods. But yet, those methods have a complicated pretreatment and a highly cost. To increase the analitical sensitivity, some preconcentration methods, such as using solid phase extraction, hava been used to combine with AAS, AFS, ICP-MS or UV Visible Spectrometer based on Flow Injection Analysis (FIA) were effective for analysis of mercury. This method can be used for determination of very low concentration of mercury with a detection limit at part per billion level. The flow injection technique has such merits as a small volume of waste, which enhances the sensitivity of the methods and allows easy connection with an automated system. Preconcentration is a method to increase an analyte concentration without standard addition.
format Theses
author NASRA , EDI
spellingShingle NASRA , EDI
PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
author_facet NASRA , EDI
author_sort NASRA , EDI
title PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
title_short PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
title_full PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
title_fullStr PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
title_full_unstemmed PRECONCENTRATION AND TRACE ANALYSIS OF Hg (II) BASED ON FLOW INJECTION ANALYSIS (FIA)
title_sort preconcentration and trace analysis of hg (ii) based on flow injection analysis (fia)
url https://digilib.itb.ac.id/gdl/view/12032
_version_ 1820728391931789312