Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode
Citrate is electroinactive, therefore citrate determination is not normally conducted using voltammetry method. In this research, a new indirect voltammetry method is developed for citrate analysis. The decrease of Fe(III) reduction current on carbon paste electrode due to complex formation of Fe(II...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/12347 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:12347 |
---|---|
spelling |
id-itb.:123472017-09-27T11:42:37ZDevelopment of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode NOVI YANTI (NIM 10505087), LUSI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12347 Citrate is electroinactive, therefore citrate determination is not normally conducted using voltammetry method. In this research, a new indirect voltammetry method is developed for citrate analysis. The decrease of Fe(III) reduction current on carbon paste electrode due to complex formation of Fe(III) and citrate was used in the analysis. The decrease of Fe(III) reduction peak is proportional to the concentration of citrate. Two voltammetry techniques, namely, differential pulse voltammetry and squerewave voltammetry was used in this study. Optimum composition carbon paste electrode contained 70% graphite and 30% paraffin. Calibration curve is linear in the range of 0,1 mM to 6 mM of citrate. The accuracy of spike sample analysis was good with percent recovery of 99,24 %-103,89%. However accuracy of citrate analysis of soft drink sample is not as good due to matrix of the sample. <br /> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Citrate is electroinactive, therefore citrate determination is not normally conducted using voltammetry method. In this research, a new indirect voltammetry method is developed for citrate analysis. The decrease of Fe(III) reduction current on carbon paste electrode due to complex formation of Fe(III) and citrate was used in the analysis. The decrease of Fe(III) reduction peak is proportional to the concentration of citrate. Two voltammetry techniques, namely, differential pulse voltammetry and squerewave voltammetry was used in this study. Optimum composition carbon paste electrode contained 70% graphite and 30% paraffin. Calibration curve is linear in the range of 0,1 mM to 6 mM of citrate. The accuracy of spike sample analysis was good with percent recovery of 99,24 %-103,89%. However accuracy of citrate analysis of soft drink sample is not as good due to matrix of the sample. <br />
|
format |
Final Project |
author |
NOVI YANTI (NIM 10505087), LUSI |
spellingShingle |
NOVI YANTI (NIM 10505087), LUSI Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
author_facet |
NOVI YANTI (NIM 10505087), LUSI |
author_sort |
NOVI YANTI (NIM 10505087), LUSI |
title |
Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
title_short |
Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
title_full |
Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
title_fullStr |
Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
title_full_unstemmed |
Development of Voltammetric Method for Citrate Analysis Using Carbon Paste Electrode |
title_sort |
development of voltammetric method for citrate analysis using carbon paste electrode |
url |
https://digilib.itb.ac.id/gdl/view/12347 |
_version_ |
1820728492561530880 |