VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE
Development of analytical methods is focused on finding new methods that are practical, fast, economical, and having high sensitivity. Many analytical methods having high sensitivity for practical uses have been developed. In the field of electroanalysis, voltammetry method is the most widely used m...
Saved in:
Main Author: | |
---|---|
Format: | Dissertations |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/12465 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:12465 |
---|---|
spelling |
id-itb.:124652017-09-27T15:45:36ZVOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE HATTU (NIM 30504011), NIKMANS Indonesia Dissertations INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12465 Development of analytical methods is focused on finding new methods that are practical, fast, economical, and having high sensitivity. Many analytical methods having high sensitivity for practical uses have been developed. In the field of electroanalysis, voltammetry method is the most widely used method to answer the challenge. This method has been proving to be able to analyze organic and inorganic analyte in trace concentration. By developing modified electrode with specific modifier combined with a compatible voltammetry technique, a more sensitive method can be obtained. Two voltammetry techniques that normally used to increase the sensitivity are square wave voltammetry and differential pulse voltammetry.<p>Voltammetry method has been used in drugs analysis that having electro-active character. Antihistamine is a medicine that has many applications. It usually used in allergic treatment. It is also used as ingredient in drug for common cold. Due to the increase of allergic prevalence, the use of antihistamine is increase significantly. Improvement in quality control of antihistamine medicine is required. Cetirizine dihydrochloride (CDC) and dextrochlorpheniramine maleate (DCM) are two of many antihistamines that are widely used. Cetirizine dihydrochloride is a second-generation antihistamine of piperazine derivate while dextro-chlorpheniramine maleate is a first generation antihistamine of propilamine derivate. Both are often used to inhibit pharmacology action of histamine competitively (H1 receptor histamine antagonist) and to handle rhinitis and urticaria symptoms.<p>Several analytical methods have been developed for the analysis of both antihistamines. In this research, new voltammetric methods were developed for voltammetric analysis of both compounds in solution containing surfactant. Voltammetric measurements were conducted using carbon paste working electrode, Ag/AgCl (3 M KCl) reference electrode and platinum wire auxiliary electrode. Carbon paste electrode was chosen as working electrode because it is easy to make, practical to use and having low residual current, while the other two electrodes are normally used in voltammetric measurements.<p>This research was aimed to find a voltammetric method for the analysis of cetirizine dihydrochloride and dextrochlorpheniramine maleate using carbon paste electrode in analyte solution containing surfactant. The surfactant was used to improve the sensitivity of analysis by accumulating analyte on the surface of carbon paste electrode. The mechanism of electron transfer on the surface of electrode was also studied. This research has provided new reliable method for antihistamine analysis and improves our understanding on surfactant role in increasing sensitivity of voltammetric analysis of organic compound. It is expected that the results can be used for development of new electrochemical analysis. <br /> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Development of analytical methods is focused on finding new methods that are practical, fast, economical, and having high sensitivity. Many analytical methods having high sensitivity for practical uses have been developed. In the field of electroanalysis, voltammetry method is the most widely used method to answer the challenge. This method has been proving to be able to analyze organic and inorganic analyte in trace concentration. By developing modified electrode with specific modifier combined with a compatible voltammetry technique, a more sensitive method can be obtained. Two voltammetry techniques that normally used to increase the sensitivity are square wave voltammetry and differential pulse voltammetry.<p>Voltammetry method has been used in drugs analysis that having electro-active character. Antihistamine is a medicine that has many applications. It usually used in allergic treatment. It is also used as ingredient in drug for common cold. Due to the increase of allergic prevalence, the use of antihistamine is increase significantly. Improvement in quality control of antihistamine medicine is required. Cetirizine dihydrochloride (CDC) and dextrochlorpheniramine maleate (DCM) are two of many antihistamines that are widely used. Cetirizine dihydrochloride is a second-generation antihistamine of piperazine derivate while dextro-chlorpheniramine maleate is a first generation antihistamine of propilamine derivate. Both are often used to inhibit pharmacology action of histamine competitively (H1 receptor histamine antagonist) and to handle rhinitis and urticaria symptoms.<p>Several analytical methods have been developed for the analysis of both antihistamines. In this research, new voltammetric methods were developed for voltammetric analysis of both compounds in solution containing surfactant. Voltammetric measurements were conducted using carbon paste working electrode, Ag/AgCl (3 M KCl) reference electrode and platinum wire auxiliary electrode. Carbon paste electrode was chosen as working electrode because it is easy to make, practical to use and having low residual current, while the other two electrodes are normally used in voltammetric measurements.<p>This research was aimed to find a voltammetric method for the analysis of cetirizine dihydrochloride and dextrochlorpheniramine maleate using carbon paste electrode in analyte solution containing surfactant. The surfactant was used to improve the sensitivity of analysis by accumulating analyte on the surface of carbon paste electrode. The mechanism of electron transfer on the surface of electrode was also studied. This research has provided new reliable method for antihistamine analysis and improves our understanding on surfactant role in increasing sensitivity of voltammetric analysis of organic compound. It is expected that the results can be used for development of new electrochemical analysis. <br />
|
format |
Dissertations |
author |
HATTU (NIM 30504011), NIKMANS |
spellingShingle |
HATTU (NIM 30504011), NIKMANS VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
author_facet |
HATTU (NIM 30504011), NIKMANS |
author_sort |
HATTU (NIM 30504011), NIKMANS |
title |
VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
title_short |
VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
title_full |
VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
title_fullStr |
VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
title_full_unstemmed |
VOLTAMMETRIC STUDY AND ANALYSIS OF CETIRIZINE DIHYDROCHLORIDE AND DEXTROCHLORPHENIRAMINE MALEATE ANTIHISTAMINES IN SURFACTANT MEDIUM BY USING CARBON PASTE ELECTRODE |
title_sort |
voltammetric study and analysis of cetirizine dihydrochloride and dextrochlorpheniramine maleate antihistamines in surfactant medium by using carbon paste electrode |
url |
https://digilib.itb.ac.id/gdl/view/12465 |
_version_ |
1820728529131667456 |