#TITLE_ALTERNATIVE#

Transient stability is the ability of the system to be stable when disturbances occur. Disturbances in power system are short circuit in transmission line, loss of unit generator and loss of loads on the system. The important things that in the transient stability analysis is how the system's a...

Full description

Saved in:
Bibliographic Details
Main Author: ADI NUGROHO (NIM 13204179), RAMADHAN
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/12530
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:12530
spelling id-itb.:125302017-09-27T10:18:36Z#TITLE_ALTERNATIVE# ADI NUGROHO (NIM 13204179), RAMADHAN Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12530 Transient stability is the ability of the system to be stable when disturbances occur. Disturbances in power system are short circuit in transmission line, loss of unit generator and loss of loads on the system. The important things that in the transient stability analysis is how the system's ability to respond to disturbances that occurs in the system. Three-phase short circuit in transmission line is related to the critical clearing time of the fault. Generator will be lost of synchronism if transient stability limit is much smaller than the relay settings of transmission line. Loss of a unit generator related to the amount of power is lost from system and the impact of another generator that interconnected to system. In this simulation shows in 2011, Circuit Breaker clearing time still under Critical Clearing Time although in some lines marginal time is small. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Transient stability is the ability of the system to be stable when disturbances occur. Disturbances in power system are short circuit in transmission line, loss of unit generator and loss of loads on the system. The important things that in the transient stability analysis is how the system's ability to respond to disturbances that occurs in the system. Three-phase short circuit in transmission line is related to the critical clearing time of the fault. Generator will be lost of synchronism if transient stability limit is much smaller than the relay settings of transmission line. Loss of a unit generator related to the amount of power is lost from system and the impact of another generator that interconnected to system. In this simulation shows in 2011, Circuit Breaker clearing time still under Critical Clearing Time although in some lines marginal time is small.
format Final Project
author ADI NUGROHO (NIM 13204179), RAMADHAN
spellingShingle ADI NUGROHO (NIM 13204179), RAMADHAN
#TITLE_ALTERNATIVE#
author_facet ADI NUGROHO (NIM 13204179), RAMADHAN
author_sort ADI NUGROHO (NIM 13204179), RAMADHAN
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/12530
_version_ 1820728547579265024