STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL
500 kV Extra High Voltage Transmission Lines, which have higher insulation level than other transmission lines with lower voltage level, should have more strength against lightning strikes. But in reality several problems appear. Broken insulators due to lightning strikes are often found in 500 kV E...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/12739 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:12739 |
---|---|
spelling |
id-itb.:127392017-09-27T15:37:39ZSTUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL LEO, TULUS Indonesia Theses Lightning Strikes to EHV lines, Broken Insulator, Extended Mast Terminal, Early Streamer Emission. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/12739 500 kV Extra High Voltage Transmission Lines, which have higher insulation level than other transmission lines with lower voltage level, should have more strength against lightning strikes. But in reality several problems appear. Broken insulators due to lightning strikes are often found in 500 kV EHV lines Paiton-Kediri. It happens especially in areas that have higher lightning density. Broken insulator can cause lack of insulation strength and potentially reduce lines performance because of the outages.<p>In order to improve transmission lines lightning performance, a new innovation had been done by using Extended Mast Terminal (EMT) attached to transmission tower. EMT is a pylon that attached at the top of transmission tower consists of Early Streamer Emission air terminal, double shielded down conductor, lightning event counter, and magnetic tape.<p>The purpose of this study is to observe the use of EMT in Transmission Lines lightning performance to reduce number of broken insulators. Installation of EMT in EHV lines Paiton Kediri had been done at the end of 2006. Result that is expected in this study is comparison of lines performance before and after innovation. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
500 kV Extra High Voltage Transmission Lines, which have higher insulation level than other transmission lines with lower voltage level, should have more strength against lightning strikes. But in reality several problems appear. Broken insulators due to lightning strikes are often found in 500 kV EHV lines Paiton-Kediri. It happens especially in areas that have higher lightning density. Broken insulator can cause lack of insulation strength and potentially reduce lines performance because of the outages.<p>In order to improve transmission lines lightning performance, a new innovation had been done by using Extended Mast Terminal (EMT) attached to transmission tower. EMT is a pylon that attached at the top of transmission tower consists of Early Streamer Emission air terminal, double shielded down conductor, lightning event counter, and magnetic tape.<p>The purpose of this study is to observe the use of EMT in Transmission Lines lightning performance to reduce number of broken insulators. Installation of EMT in EHV lines Paiton Kediri had been done at the end of 2006. Result that is expected in this study is comparison of lines performance before and after innovation.
|
format |
Theses |
author |
LEO, TULUS |
spellingShingle |
LEO, TULUS STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
author_facet |
LEO, TULUS |
author_sort |
LEO, TULUS |
title |
STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
title_short |
STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
title_full |
STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
title_fullStr |
STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
title_full_unstemmed |
STUDY OF LIGHTNING PROTECTION SYSTEM IMPROVEMENT ON EXTRA HIGH VOLTAGE 500 KV TRANSMISSION LINES IN TROPICAL AREA USING EXTENDED MAST TERMINAL |
title_sort |
study of lightning protection system improvement on extra high voltage 500 kv transmission lines in tropical area using extended mast terminal |
url |
https://digilib.itb.ac.id/gdl/view/12739 |
_version_ |
1820728610071248896 |