#TITLE_ALTERNATIVE#

Relay is one of the important protective device in the protection of power system. Relay give order to circuit breaker to open if fault happens. In the high voltage transmission system, directional overcurrent relay and distance relay are often used as the main component of protection system. It...

全面介紹

Saved in:
書目詳細資料
主要作者: JULIUS HUTAGALUNG , MERLIN
格式: Final Project
語言:Indonesia
在線閱讀:https://digilib.itb.ac.id/gdl/view/13031
標簽: 添加標簽
沒有標簽, 成為第一個標記此記錄!
id id-itb.:13031
spelling id-itb.:130312017-09-27T10:18:43Z#TITLE_ALTERNATIVE# JULIUS HUTAGALUNG , MERLIN Indonesia Final Project Coordination directional overcurrent relay and distance relay, coordination interval (CI), TMS (Time Multiple Setting),Tz2, optimazion INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/13031 Relay is one of the important protective device in the protection of power system. Relay give order to circuit breaker to open if fault happens. In the high voltage transmission system, directional overcurrent relay and distance relay are often used as the main component of protection system. It's easy to calculate the coordination of overcurrent relay and distance relay manually. But in the more complex system, consists of many source and load, it can be difficult. Because of that an optimazion method is needed to solve the problem quickly, efficiently and simultaneously.<p>This final project study about optimazion of directional overcurrent relay and distance relay's coordination in complex system. The coordination equation is outlined in linier equation, with TMS (Time Multiple Setting) and Tz2 (Distance relay second zone) as an optimized value. The objective is to get minimum operating time without violating Coordination Interval (CI). The optimazion method has been simulated in radial system, 8-bus 7 lines IEEE. The simulation result shown that this optimazion method had succeed to solve the relay coordination problems efficiently, quickly and simultaneously. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Relay is one of the important protective device in the protection of power system. Relay give order to circuit breaker to open if fault happens. In the high voltage transmission system, directional overcurrent relay and distance relay are often used as the main component of protection system. It's easy to calculate the coordination of overcurrent relay and distance relay manually. But in the more complex system, consists of many source and load, it can be difficult. Because of that an optimazion method is needed to solve the problem quickly, efficiently and simultaneously.<p>This final project study about optimazion of directional overcurrent relay and distance relay's coordination in complex system. The coordination equation is outlined in linier equation, with TMS (Time Multiple Setting) and Tz2 (Distance relay second zone) as an optimized value. The objective is to get minimum operating time without violating Coordination Interval (CI). The optimazion method has been simulated in radial system, 8-bus 7 lines IEEE. The simulation result shown that this optimazion method had succeed to solve the relay coordination problems efficiently, quickly and simultaneously.
format Final Project
author JULIUS HUTAGALUNG , MERLIN
spellingShingle JULIUS HUTAGALUNG , MERLIN
#TITLE_ALTERNATIVE#
author_facet JULIUS HUTAGALUNG , MERLIN
author_sort JULIUS HUTAGALUNG , MERLIN
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/13031
_version_ 1825533707072569344