Configurations of Two Winding Interphase Transformers (2-I1'Ts) for paralleling high current low voltage rectifiers are analyzed to meet optimum configuration in aspect of number and total VA rating required for a number of N inputs. Then, the rectifier's current ripples of these configura...

Full description

Saved in:
Bibliographic Details
Main Author: IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/13680
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:13680
spelling id-itb.:136802017-09-27T15:37:38Z#TITLE_ALTERNATIVE# IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/13680 Configurations of Two Winding Interphase Transformers (2-I1'Ts) for paralleling high current low voltage rectifiers are analyzed to meet optimum configuration in aspect of number and total VA rating required for a number of N inputs. Then, the rectifier's current ripples of these configurations are analyzed. The research takes a case study for paralleling three one-phase rectifiers from secondary side of three-phase transformer.<p>Analysis and experiment show that the combinatorial shunt configuration is the most advantageous in the aspect of the total rating, but the most disadvantageous in the aspect of number of 2-IPTs.<p>In the aspect of number of 2-IPTs, secondary loop, cyclic cascade and cyclic shunt are the most advantageous configurations., The experiment is also show that the positive polarity of 2-IPTs gives high current ripple on the phase side and low ripple on the load side but gives current discontinuity on phase side, on the contrary, the negative polarity gives low current ripple on the phase side and high ripple on the load side but its give continuity of current on phase side. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Configurations of Two Winding Interphase Transformers (2-I1'Ts) for paralleling high current low voltage rectifiers are analyzed to meet optimum configuration in aspect of number and total VA rating required for a number of N inputs. Then, the rectifier's current ripples of these configurations are analyzed. The research takes a case study for paralleling three one-phase rectifiers from secondary side of three-phase transformer.<p>Analysis and experiment show that the combinatorial shunt configuration is the most advantageous in the aspect of the total rating, but the most disadvantageous in the aspect of number of 2-IPTs.<p>In the aspect of number of 2-IPTs, secondary loop, cyclic cascade and cyclic shunt are the most advantageous configurations., The experiment is also show that the positive polarity of 2-IPTs gives high current ripple on the phase side and low ripple on the load side but gives current discontinuity on phase side, on the contrary, the negative polarity gives low current ripple on the phase side and high ripple on the load side but its give continuity of current on phase side.
format Theses
author IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD
spellingShingle IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD
#TITLE_ALTERNATIVE#
author_facet IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD
author_sort IMRAN HAMID (NIM 23298508); Pembimbing: Dr.Ir. Pekik Argo Dahono, MUHAMMAD
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/13680
_version_ 1820736257458700288