MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA

More and more studies have proved that the level of danger from air pollution indoors can be higher than outdoor air pollution. One factor that may increase air pollution in a house is intrusion from outside the home, for example from transport emissions. Nitrogen oxides (NOx) is one of the importan...

Full description

Saved in:
Bibliographic Details
Main Author: RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/14412
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:14412
spelling id-itb.:144122017-09-27T10:25:15ZMEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/14412 More and more studies have proved that the level of danger from air pollution indoors can be higher than outdoor air pollution. One factor that may increase air pollution in a house is intrusion from outside the home, for example from transport emissions. Nitrogen oxides (NOx) is one of the important pollutants from transportation activities. Therefore, this study aims to measure the concentration of NOx in the form of NO2 in the house and see its relation with asthma. NO2 in the home can be sourced from outside the home, can also be sourced from within the home such as gas flaring in the kitchen and tobacco smoke. From several studies found that NO2 has a significant relationship to asthma. In this case study is conducted NO2 measurements using passive sampler mounted on the living room, bedroom, and kitchens in 100 homes with 70 homes asthmatic and 30 non-asthma (control). Also done interviews related activities and sources of NO2 occupants in the house which was then analyzed. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description More and more studies have proved that the level of danger from air pollution indoors can be higher than outdoor air pollution. One factor that may increase air pollution in a house is intrusion from outside the home, for example from transport emissions. Nitrogen oxides (NOx) is one of the important pollutants from transportation activities. Therefore, this study aims to measure the concentration of NOx in the form of NO2 in the house and see its relation with asthma. NO2 in the home can be sourced from outside the home, can also be sourced from within the home such as gas flaring in the kitchen and tobacco smoke. From several studies found that NO2 has a significant relationship to asthma. In this case study is conducted NO2 measurements using passive sampler mounted on the living room, bedroom, and kitchens in 100 homes with 70 homes asthmatic and 30 non-asthma (control). Also done interviews related activities and sources of NO2 occupants in the house which was then analyzed.
format Final Project
author RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH
spellingShingle RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH
MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
author_facet RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH
author_sort RETNO PURWANINGRUM (NIM 15306023); Pembimbing: Ir. Raden Driejena, MSCE., Ph.D., RATIH
title MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
title_short MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
title_full MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
title_fullStr MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
title_full_unstemmed MEASUREMENT CONCENTRATION OF NITROGEN DIOXIDE (NO2) INSIDE HOUSE AND ITS RELATION WITH ASTHMA
title_sort measurement concentration of nitrogen dioxide (no2) inside house and its relation with asthma
url https://digilib.itb.ac.id/gdl/view/14412
_version_ 1820737209284689920