Paracetamol is a common analgesic drug that is used to relief fever and headaches. Nevertheless, when consumed in overdose quantities, it may cause severe hepatic toxicity or death. Therefore, the development of precise and accurate methods for determination of paracetamol is necessary. In this stud...

Full description

Saved in:
Bibliographic Details
Main Author: MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/14446
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:14446
spelling id-itb.:144462017-09-27T11:42:33Z#TITLE_ALTERNATIVE# MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/14446 Paracetamol is a common analgesic drug that is used to relief fever and headaches. Nevertheless, when consumed in overdose quantities, it may cause severe hepatic toxicity or death. Therefore, the development of precise and accurate methods for determination of paracetamol is necessary. In this study, a chronoamperometric technique using biosensor has been developed to determine paracetamol. Carbon paste electrode modified with avocado or banana tissue as the source of polyphenol oxidase is used as biosensor. Polyphenol oxidase <br /> <br /> <br /> <br /> <br /> enzyme is used to catalyze oxidation of paracetamol into N-acetyl-p-benzoquinoneimine. This product is reduced at certain potential using chronoamperometric technique for quantitative analysis. The calibration curve of paracetamol standards is highly linear in the concentration range of 3,97x10(-4)–4,12x10(-3)M. Determination of percent recovery shows that the developed method has good accuracy for paracetamol analysis. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Paracetamol is a common analgesic drug that is used to relief fever and headaches. Nevertheless, when consumed in overdose quantities, it may cause severe hepatic toxicity or death. Therefore, the development of precise and accurate methods for determination of paracetamol is necessary. In this study, a chronoamperometric technique using biosensor has been developed to determine paracetamol. Carbon paste electrode modified with avocado or banana tissue as the source of polyphenol oxidase is used as biosensor. Polyphenol oxidase <br /> <br /> <br /> <br /> <br /> enzyme is used to catalyze oxidation of paracetamol into N-acetyl-p-benzoquinoneimine. This product is reduced at certain potential using chronoamperometric technique for quantitative analysis. The calibration curve of paracetamol standards is highly linear in the concentration range of 3,97x10(-4)–4,12x10(-3)M. Determination of percent recovery shows that the developed method has good accuracy for paracetamol analysis.
format Final Project
author MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG
spellingShingle MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG
#TITLE_ALTERNATIVE#
author_facet MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG
author_sort MAHENDRA (NIM 10503065); Pembimbing : Dr. Indra Noviandri, RISANG
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/14446
_version_ 1820737219961290752