SISTIM PERAWATAN BETON SEBAGAI SALAH SATU PENENTU TINGKAT KESESUAIAN PARSIAL STRUKTUR BETON

Some curing methods, i.e. immersion, covering and membrane methods, were studied to analyse degree of conformance (DOC) to specification, that take strength and permeability of K300, K500 and K800 as points of view. Result. of K300 test show that all of curing methods produce DOC more than 100%. Mem...

Full description

Saved in:
Bibliographic Details
Main Author: Paing Heru Waskito, johan
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/1447
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
Description
Summary:Some curing methods, i.e. immersion, covering and membrane methods, were studied to analyse degree of conformance (DOC) to specification, that take strength and permeability of K300, K500 and K800 as points of view. Result. of K300 test show that all of curing methods produce DOC more than 100%. Membrane methods specimen of K500 is 97% DOC, the others are more than 100% DOC. Result of K800 test show that degree of conformance membrane method to immersion or covering method is 70%. Cost analysis show that 9,7% adding cost of K300 can prevent risk to lost about 25%, and 9% adding cost of K500 and K800 can prevent risk to lost about 40%. Some influence were obtained in this study, i.e. temperature variation, removal formwork, dimension, labour, inspection, natural influence, environment and any trouble.