DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A

Depletion of the ozone layer that occurred has resulted various international conventions to reduce and discontinue the use of HCFCs and CFCs. R-22 is one of HCFC refrigerants that could potentially damage the ozone so that its use will be reduced to 10% in 2015 under the Montreal Protocol. As an al...

Full description

Saved in:
Bibliographic Details
Main Author: ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/15597
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:15597
spelling id-itb.:155972017-09-27T10:40:54ZDESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/15597 Depletion of the ozone layer that occurred has resulted various international conventions to reduce and discontinue the use of HCFCs and CFCs. R-22 is one of HCFC refrigerants that could potentially damage the ozone so that its use will be reduced to 10% in 2015 under the Montreal Protocol. As an alternative refrigerant, R410-A has a characteristics that are close to R-22 and zero ODP (Ozone depletion Potential). The purpose of this research is to design an air conditioning machine with the refrigerant R-410A as an alternative refrigerant of R-22 and to determine the condition of its operations by doing simulations. The design includes a compressor and expansion valve selection and design of finned tube heat exchanger as the evaporator and condenser. The design of heat exchanger is done using the commercial software and using manual calculations. The <br /> <br /> <br /> manual calculations design also performed for R-22 so it can be compared with the results of the design for R-410A. <br /> <br /> <br /> This design results a configuration and dimensions of the heat exchanger and its differences between design by software and manual. In the evaporator, the difference in the area of heat exchanger is 14% with manual design has a <br /> <br /> <br /> greater finned width, while in the condenser by 38% with smaller finned width in manual design. The R-22 heat exchanger manual designed has a slightly differences total area from R-410A heat exchanger, which are 3% for evaporator and 7% for condenser. The simulation results showed the COP is 5,31, 3,92, and 3,00 for each 1800, 3600, and 5400 rpm compressor. As a conclusion, there is a difference in the value of heat transfer coefficient (U) between the software and manual calculations so that resulting a difference in a heat transfer surface area (A). This differences of U is caused by the differences of the heat exchanger configuration and model of refrigerant <br /> <br /> <br /> flow. The surface area for heat transfer in the evaporator dan condenser designed by software are respectively 86,45 m2 and 89,13 m2 while the manual design is 81,31 m2 and 55,2 m2. The conclusions from simulation results is the <br /> <br /> <br /> COP machine at design conditions is at 3,00 , this value is still above the COP recommendation from Indonesia National Standard, which is 2,60. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Depletion of the ozone layer that occurred has resulted various international conventions to reduce and discontinue the use of HCFCs and CFCs. R-22 is one of HCFC refrigerants that could potentially damage the ozone so that its use will be reduced to 10% in 2015 under the Montreal Protocol. As an alternative refrigerant, R410-A has a characteristics that are close to R-22 and zero ODP (Ozone depletion Potential). The purpose of this research is to design an air conditioning machine with the refrigerant R-410A as an alternative refrigerant of R-22 and to determine the condition of its operations by doing simulations. The design includes a compressor and expansion valve selection and design of finned tube heat exchanger as the evaporator and condenser. The design of heat exchanger is done using the commercial software and using manual calculations. The <br /> <br /> <br /> manual calculations design also performed for R-22 so it can be compared with the results of the design for R-410A. <br /> <br /> <br /> This design results a configuration and dimensions of the heat exchanger and its differences between design by software and manual. In the evaporator, the difference in the area of heat exchanger is 14% with manual design has a <br /> <br /> <br /> greater finned width, while in the condenser by 38% with smaller finned width in manual design. The R-22 heat exchanger manual designed has a slightly differences total area from R-410A heat exchanger, which are 3% for evaporator and 7% for condenser. The simulation results showed the COP is 5,31, 3,92, and 3,00 for each 1800, 3600, and 5400 rpm compressor. As a conclusion, there is a difference in the value of heat transfer coefficient (U) between the software and manual calculations so that resulting a difference in a heat transfer surface area (A). This differences of U is caused by the differences of the heat exchanger configuration and model of refrigerant <br /> <br /> <br /> flow. The surface area for heat transfer in the evaporator dan condenser designed by software are respectively 86,45 m2 and 89,13 m2 while the manual design is 81,31 m2 and 55,2 m2. The conclusions from simulation results is the <br /> <br /> <br /> COP machine at design conditions is at 3,00 , this value is still above the COP recommendation from Indonesia National Standard, which is 2,60.
format Final Project
author ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI
spellingShingle ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI
DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
author_facet ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI
author_sort ABDILLAH (NIM : 13107092); Pembimbing : Dr. Ir. Ari Darmawan Pasek, FAHMI
title DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
title_short DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
title_full DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
title_fullStr DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
title_full_unstemmed DESIGN AND SIMULATION OF AIR CONDITIONING MACHINE WITH CAPACITY OF 50 KW USING R-410A
title_sort design and simulation of air conditioning machine with capacity of 50 kw using r-410a
url https://digilib.itb.ac.id/gdl/view/15597
_version_ 1820737502050254848