EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER

In this final project is to develop an integrated solar water heater with flat plate type. The design aims to improve the performance of an existing design. In addition, the design and manufacture of integrated solar water heater vertical cylinder type, as the basic design approach and integrated wa...

Full description

Saved in:
Bibliographic Details
Main Author: FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/15900
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:15900
spelling id-itb.:159002017-09-27T10:40:52ZEXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/15900 In this final project is to develop an integrated solar water heater with flat plate type. The design aims to improve the performance of an existing design. In addition, the design and manufacture of integrated solar water heater vertical cylinder type, as the basic design approach and integrated water heater comparison type flat plate. Efforts to improve the performance of integrated solar water heating flat plate type is done by adding the transparent cover on top of a storage tank-type solar water heater absorber. <br /> <br /> <br /> As a result of a series of design, produced an integrated flat plate solar water heater that has been tested with the aim to get a solar water heater which is relatively cheap compared with the water heater solar system on the market. Integrated solar water heating system where hot water tank and absorber incorporated into one. Type of solar water heaters integrated flat plate consists of three blocks that have size (100x30x10) cm, so have the 90 liter volume. Tests carried out on the roof of the Mechanical Engineering Laboratory Surya Bandung Institute of Technology with a height of about 10 meter. <br /> <br /> <br /> Based on testing, the water temperature is obtained, the approximate temperature of the output, an integrated type solar water heater flat plate at 48 oC in the afternoon on a high solar radiation and equitable . Performance improvement compared to previous designs is the 4.7% seen from the achievements of the water temperature. There is a difference between sample temperatures of 10.7 oC higher towards integrated solar water heater vertical cylinder type, this is because the projected area of absorber which is owned by an integrated solar water heater vertical cylinder type is smaller than the integrated solar water heating flat plate type. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description In this final project is to develop an integrated solar water heater with flat plate type. The design aims to improve the performance of an existing design. In addition, the design and manufacture of integrated solar water heater vertical cylinder type, as the basic design approach and integrated water heater comparison type flat plate. Efforts to improve the performance of integrated solar water heating flat plate type is done by adding the transparent cover on top of a storage tank-type solar water heater absorber. <br /> <br /> <br /> As a result of a series of design, produced an integrated flat plate solar water heater that has been tested with the aim to get a solar water heater which is relatively cheap compared with the water heater solar system on the market. Integrated solar water heating system where hot water tank and absorber incorporated into one. Type of solar water heaters integrated flat plate consists of three blocks that have size (100x30x10) cm, so have the 90 liter volume. Tests carried out on the roof of the Mechanical Engineering Laboratory Surya Bandung Institute of Technology with a height of about 10 meter. <br /> <br /> <br /> Based on testing, the water temperature is obtained, the approximate temperature of the output, an integrated type solar water heater flat plate at 48 oC in the afternoon on a high solar radiation and equitable . Performance improvement compared to previous designs is the 4.7% seen from the achievements of the water temperature. There is a difference between sample temperatures of 10.7 oC higher towards integrated solar water heater vertical cylinder type, this is because the projected area of absorber which is owned by an integrated solar water heater vertical cylinder type is smaller than the integrated solar water heating flat plate type.
format Final Project
author FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO
spellingShingle FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO
EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
author_facet FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO
author_sort FITRIADI ARYO DWIPO (NIM : 13106004); Dosen Pembimbing, : Dr. Ir. Abdurrachim Halim, HENDRO
title EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
title_short EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
title_full EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
title_fullStr EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
title_full_unstemmed EXPERIMENTAL STUDY ON INTERGRATED FLAT PLATE SOLAR WATER HEATER
title_sort experimental study on intergrated flat plate solar water heater
url https://digilib.itb.ac.id/gdl/view/15900
_version_ 1820737574672531456