SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL

In many commercial buildings such as hotels and offices. Usually, the requirement of cold air is handled by an air conditioning system. Whereas, the requirement of hot water is handled by electric heater. The heat from the refrigeration machine released to surrounding usually has utilization. In thi...

Full description

Saved in:
Bibliographic Details
Main Author: IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/16901
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:16901
spelling id-itb.:169012017-09-27T14:53:50ZSIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/16901 In many commercial buildings such as hotels and offices. Usually, the requirement of cold air is handled by an air conditioning system. Whereas, the requirement of hot water is handled by electric heater. The heat from the refrigeration machine released to surrounding usually has utilization. In this simulation, it is studied utilizing chiller heat waste for hot water requirement. <br /> <br /> <br /> Result of simulation indicate that average of energy can be used for heating up water is 383901,221 kj. It can increase temperature of 2500 liter water until 56 oC in 67 minute if chiller operates continually. Results of simulation <br /> <br /> <br /> indicate that using isolator can save energy 0,194 KWh every heating periodic. Energy can be saved using of electic water heater until 90 % from energy used for heating up 2500 liter water from 20 oC - 60 oC using electric water heater. <br /> <br /> <br /> In the peak time of water utilization , result of simulation indicate for using 400 liter water every 15 minute (1600 liter per hour). Water temperatur is still kept warm until 47 oC. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description In many commercial buildings such as hotels and offices. Usually, the requirement of cold air is handled by an air conditioning system. Whereas, the requirement of hot water is handled by electric heater. The heat from the refrigeration machine released to surrounding usually has utilization. In this simulation, it is studied utilizing chiller heat waste for hot water requirement. <br /> <br /> <br /> Result of simulation indicate that average of energy can be used for heating up water is 383901,221 kj. It can increase temperature of 2500 liter water until 56 oC in 67 minute if chiller operates continually. Results of simulation <br /> <br /> <br /> indicate that using isolator can save energy 0,194 KWh every heating periodic. Energy can be saved using of electic water heater until 90 % from energy used for heating up 2500 liter water from 20 oC - 60 oC using electric water heater. <br /> <br /> <br /> In the peak time of water utilization , result of simulation indicate for using 400 liter water every 15 minute (1600 liter per hour). Water temperatur is still kept warm until 47 oC.
format Theses
author IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT
spellingShingle IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT
SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
author_facet IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT
author_sort IMAN MAINIL (NIM : 23109002); Dosen Pembimbing : Dr. Ir. Abdurrachim, RAHMAT
title SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
title_short SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
title_full SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
title_fullStr SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
title_full_unstemmed SIMULATION OF UTILIZING CHILLER HEAT WASTE FOR HOT WATER REQUIREMENT IN HOTEL
title_sort simulation of utilizing chiller heat waste for hot water requirement in hotel
url https://digilib.itb.ac.id/gdl/view/16901
_version_ 1820745486057865216