IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES

Magnetic Resonance Imaging (MRI) is an imaging technique which utilizes magnetic moment property of the nucleus inside of body. Resonance will make the protons emit an electromagnetic wave which then will be processed to make an image. Pulse Sequence determines what kind of image that will be obtain...

Full description

Saved in:
Bibliographic Details
Main Author: RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/16993
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:16993
spelling id-itb.:169932017-09-27T11:45:08ZIMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto, Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/16993 Magnetic Resonance Imaging (MRI) is an imaging technique which utilizes magnetic moment property of the nucleus inside of body. Resonance will make the protons emit an electromagnetic wave which then will be processed to make an image. Pulse Sequence determines what kind of image that will be obtained. Sequences can be chosen using the right parameters. In MRI, some of the sequences are Spin Echo, Turbo Spin Echo and Fluid-Attenuated Inversion Recovery (FLAIR). In this study, images from those three sequences were obtained and processed. The images were obtained using an 1,5 Tesla MRI device at Santosa Bandung Interational Hospital using the library parameters. The image histograms were extracted from each image and were treated using statistik data analysis. The result of the calculation will show the characteristic of every sequence. Anatomical images are obtained from Spin Echo with T1-weighting, pathological images are obtained from Turbo Spin Echo with T2-weighting, and FLAIR can detects stroke disease. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Magnetic Resonance Imaging (MRI) is an imaging technique which utilizes magnetic moment property of the nucleus inside of body. Resonance will make the protons emit an electromagnetic wave which then will be processed to make an image. Pulse Sequence determines what kind of image that will be obtained. Sequences can be chosen using the right parameters. In MRI, some of the sequences are Spin Echo, Turbo Spin Echo and Fluid-Attenuated Inversion Recovery (FLAIR). In this study, images from those three sequences were obtained and processed. The images were obtained using an 1,5 Tesla MRI device at Santosa Bandung Interational Hospital using the library parameters. The image histograms were extracted from each image and were treated using statistik data analysis. The result of the calculation will show the characteristic of every sequence. Anatomical images are obtained from Spin Echo with T1-weighting, pathological images are obtained from Turbo Spin Echo with T2-weighting, and FLAIR can detects stroke disease.
format Final Project
author RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto,
spellingShingle RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto,
IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
author_facet RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto,
author_sort RIBKA SETIAWATI (NIM:10207010); Pembimbing : Dr. rer.nat. Freddy Haryanto,
title IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
title_short IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
title_full IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
title_fullStr IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
title_full_unstemmed IMAGE COMPARISON OF SPIN ECHO, TURBO SPIN ECHO AND FLUID ATTENUATED INVERSION RECOVERY TO MRI USING HISTOGRAM IMAGES
title_sort image comparison of spin echo, turbo spin echo and fluid attenuated inversion recovery to mri using histogram images
url https://digilib.itb.ac.id/gdl/view/16993
_version_ 1820745507269509120