SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK

Detection and processing system of spectroscopy absorption signal for electronic simulated laser frequency stabilization Laser frequency stabilization with absorption line reference needs a high signal to noise ratio (S/N) line frequency absorption detection system. For these purposes, detection and...

Full description

Saved in:
Bibliographic Details
Main Author: Chusno Trijanto, Anang
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/1807
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:1807
spelling id-itb.:18072004-12-06T16:29:08ZSISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK Chusno Trijanto, Anang Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/1807 Detection and processing system of spectroscopy absorption signal for electronic simulated laser frequency stabilization Laser frequency stabilization with absorption line reference needs a high signal to noise ratio (S/N) line frequency absorption detection system. For these purposes, detection and processing system of spectroscopy absorption signal has been developed. The system identifies the peak of absorption curve by mean of scan around the curve. For study and analyzing purposes, Lorentzian model is implemented to off-line process. However, in frequency stabilization, parabolic model is implemented around the top of the curve. This is expected to improve the long-term stability of laser frequency control system, by decreasing Allan Standard Deviation, ay.(t), at i z, 100 s up to 1000 s or more. This method is then applied on a 12 MHz electronic absorption simulator. The test result demonstrates that Lorentzian approach has constraint due the difficulty of analytic evaluation for on-line implementation. While with parabolic approach these difficulties are not shown. The resulting deviation standard a = 1.26E-01 and a = 1. 39E-01. Its higher than, but relatively close to that of Lorentzian approach a = 1.05 E-01. In frequency stabilization, peak identification is then use as a basic data to produce correction signal that will shift the output frequency. Stability analyzing in time domain, show that Allan Standard Deviation, a(t), decreases at 100 s 5 T 5 1000 s but it increases at 1 s 5 t 5 20 s. It shows that S/N improvement occurs at 100 s 5. z 5 1000 s, that mean long-term stability is improved. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Detection and processing system of spectroscopy absorption signal for electronic simulated laser frequency stabilization Laser frequency stabilization with absorption line reference needs a high signal to noise ratio (S/N) line frequency absorption detection system. For these purposes, detection and processing system of spectroscopy absorption signal has been developed. The system identifies the peak of absorption curve by mean of scan around the curve. For study and analyzing purposes, Lorentzian model is implemented to off-line process. However, in frequency stabilization, parabolic model is implemented around the top of the curve. This is expected to improve the long-term stability of laser frequency control system, by decreasing Allan Standard Deviation, ay.(t), at i z, 100 s up to 1000 s or more. This method is then applied on a 12 MHz electronic absorption simulator. The test result demonstrates that Lorentzian approach has constraint due the difficulty of analytic evaluation for on-line implementation. While with parabolic approach these difficulties are not shown. The resulting deviation standard a = 1.26E-01 and a = 1. 39E-01. Its higher than, but relatively close to that of Lorentzian approach a = 1.05 E-01. In frequency stabilization, peak identification is then use as a basic data to produce correction signal that will shift the output frequency. Stability analyzing in time domain, show that Allan Standard Deviation, a(t), decreases at 100 s 5 T 5 1000 s but it increases at 1 s 5 t 5 20 s. It shows that S/N improvement occurs at 100 s 5. z 5 1000 s, that mean long-term stability is improved.
format Theses
author Chusno Trijanto, Anang
spellingShingle Chusno Trijanto, Anang
SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
author_facet Chusno Trijanto, Anang
author_sort Chusno Trijanto, Anang
title SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
title_short SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
title_full SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
title_fullStr SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
title_full_unstemmed SISTEM DETEKSI DAN PEMROSESAN SINYAL ABSORPSI SPEKTROSKOPI UNTUK PENSTABILAN FREKUENSI LASER YANG DISIMULASIKAN SECARA ELEKTRONIK
title_sort sistem deteksi dan pemrosesan sinyal absorpsi spektroskopi untuk penstabilan frekuensi laser yang disimulasikan secara elektronik
url https://digilib.itb.ac.id/gdl/view/1807
_version_ 1820663067699052544