#TITLE_ALTERNATIVE#

The foundation is part of the structure which has an important role to continue the loadfrom the upper structure to the ground. Planning foundation must meet safety requirements. Safety factor that must be met, among others, the magnitude of the forcesacting on the pole must be smaller than the pole...

Full description

Saved in:
Bibliographic Details
Main Author: SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/19337
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:19337
spelling id-itb.:193372017-09-27T10:25:48Z#TITLE_ALTERNATIVE# SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/19337 The foundation is part of the structure which has an important role to continue the loadfrom the upper structure to the ground. Planning foundation must meet safety requirements. Safety factor that must be met, among others, the magnitude of the forcesacting on the pole must be smaller than the pole ulitimit capacity, the amount of the soil bearing capacity of foundation system, the deflection that occurs must be within deflection permits, as well as the magnitude of decline (settlement) will occur in the foundation system. This final task containing of foundation design oil tank with a capacity of 5000 MT with theuse of deep foundation driven piles are located on Sea Island South Kalimantan. In this final discussion is limited to Determining the diameter and length of the foundation that will be used by considering the deflection of the head pole. Methods to be Used in designing the foundation to this thesis is API method's with Cu based on SPT and using a computer program APILE, LPILE, GPILE, Plaxis 3D Foundation. Piles to be used is piling produced by PT Wika Beton text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The foundation is part of the structure which has an important role to continue the loadfrom the upper structure to the ground. Planning foundation must meet safety requirements. Safety factor that must be met, among others, the magnitude of the forcesacting on the pole must be smaller than the pole ulitimit capacity, the amount of the soil bearing capacity of foundation system, the deflection that occurs must be within deflection permits, as well as the magnitude of decline (settlement) will occur in the foundation system. This final task containing of foundation design oil tank with a capacity of 5000 MT with theuse of deep foundation driven piles are located on Sea Island South Kalimantan. In this final discussion is limited to Determining the diameter and length of the foundation that will be used by considering the deflection of the head pole. Methods to be Used in designing the foundation to this thesis is API method's with Cu based on SPT and using a computer program APILE, LPILE, GPILE, Plaxis 3D Foundation. Piles to be used is piling produced by PT Wika Beton
format Final Project
author SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN
spellingShingle SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN
#TITLE_ALTERNATIVE#
author_facet SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN
author_sort SIMANJORANG (NIM : 15007066) ; Pembimbing : Hasbullah Nawir, ST., MT., Ph.D., RISMAN
title #TITLE_ALTERNATIVE#
title_short #TITLE_ALTERNATIVE#
title_full #TITLE_ALTERNATIVE#
title_fullStr #TITLE_ALTERNATIVE#
title_full_unstemmed #TITLE_ALTERNATIVE#
title_sort #title_alternative#
url https://digilib.itb.ac.id/gdl/view/19337
_version_ 1821119808417038336