PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY
The main goal of radiotherapy treatment is the irradiation of a target volume while minimizing the amount of radiation absorbed in healthy tissue. Multileaf Collimator (MLC) is one of method to achieve this goal. This study aims to investigate the effect of MLC transmission on dose calculation in Pr...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/19980 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:19980 |
---|---|
spelling |
id-itb.:199802017-09-27T14:41:03ZPRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY NISA (NIM : 20212003); Pembimbing : Dr. rer.nat Freddy Haryanto, CHAIRUN Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/19980 The main goal of radiotherapy treatment is the irradiation of a target volume while minimizing the amount of radiation absorbed in healthy tissue. Multileaf Collimator (MLC) is one of method to achieve this goal. This study aims to investigate the effect of MLC transmission on dose calculation in Prism TPS MLC transmission can be investigated by measuring the dose at depth of dmax while MLC leaves open with field size of 10 x 10 cm2 and closed with field size 0.6 x 40 cm2 at SSD 100 cm , then compare between them and see how the dose distribution in the profile graph. In this study do several variations they are energy, field size, profile depth and monitors unit. Based on dose calculation have done by Prism, MLC transmission effected by energy, field size, profile depth and monitors unit text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The main goal of radiotherapy treatment is the irradiation of a target volume while minimizing the amount of radiation absorbed in healthy tissue. Multileaf Collimator (MLC) is one of method to achieve this goal. This study aims to investigate the effect of MLC transmission on dose calculation in Prism TPS MLC transmission can be investigated by measuring the dose at depth of dmax while MLC leaves open with field size of 10 x 10 cm2 and closed with field size 0.6 x 40 cm2 at SSD 100 cm , then compare between them and see how the dose distribution in the profile graph. In this study do several variations they are energy, field size, profile depth and monitors unit. Based on dose calculation have done by Prism, MLC transmission effected by energy, field size, profile depth and monitors unit |
format |
Theses |
author |
NISA (NIM : 20212003); Pembimbing : Dr. rer.nat Freddy Haryanto, CHAIRUN |
spellingShingle |
NISA (NIM : 20212003); Pembimbing : Dr. rer.nat Freddy Haryanto, CHAIRUN PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
author_facet |
NISA (NIM : 20212003); Pembimbing : Dr. rer.nat Freddy Haryanto, CHAIRUN |
author_sort |
NISA (NIM : 20212003); Pembimbing : Dr. rer.nat Freddy Haryanto, CHAIRUN |
title |
PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
title_short |
PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
title_full |
PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
title_fullStr |
PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
title_full_unstemmed |
PRELIMINARY STUDY THE EFFECT OF MULTILEAF COLLIMATOR (MLC) TRANSMISSION ON DOSE CALCULATION BASICLY |
title_sort |
preliminary study the effect of multileaf collimator (mlc) transmission on dose calculation basicly |
url |
https://digilib.itb.ac.id/gdl/view/19980 |
_version_ |
1822919711701073920 |