LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS

Electrical energy is very important in human life. Rapid population growth resulting in increased electricity needs in Indonesia. Therefore PLN as a provider of electrical energy as possible to meet those needs. One step that is done is to plan to build a 500 kV transmission line in Sumatera. With t...

Full description

Saved in:
Bibliographic Details
Main Author: JUNAIDI (NIM : 23214099), ANDI
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/21041
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:21041
spelling id-itb.:210412017-09-27T15:37:43ZLIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS JUNAIDI (NIM : 23214099), ANDI Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/21041 Electrical energy is very important in human life. Rapid population growth resulting in increased electricity needs in Indonesia. Therefore PLN as a provider of electrical energy as possible to meet those needs. One step that is done is to plan to build a 500 kV transmission line in Sumatera. With the planned construction of the transmission line, it is also necessary planning for the distribution of electrical energy by analyzing the reliability of the transmission line against lightning strikes disorders. In this final project will be discussed on the development planning of 500 kV transmission line by comparing the two models of transmission line towers. The first model is a transmission line with two circuits and two ground wire, where the height of the tower is 71.625 meters. While the second model of the tower is a transmission line with 4 circuits and 2 ground wire, with a height of 108.545 meter transmission tower. Of the two types of transmission towers will be analyzed against lightning strikes of lightning performance of each of the transmission tower. 500 kV transmission line is expected to supply electrical energy and increase the reliability of the electricity system in Sumatra area which is an area with electrical energy demand is high enough. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Electrical energy is very important in human life. Rapid population growth resulting in increased electricity needs in Indonesia. Therefore PLN as a provider of electrical energy as possible to meet those needs. One step that is done is to plan to build a 500 kV transmission line in Sumatera. With the planned construction of the transmission line, it is also necessary planning for the distribution of electrical energy by analyzing the reliability of the transmission line against lightning strikes disorders. In this final project will be discussed on the development planning of 500 kV transmission line by comparing the two models of transmission line towers. The first model is a transmission line with two circuits and two ground wire, where the height of the tower is 71.625 meters. While the second model of the tower is a transmission line with 4 circuits and 2 ground wire, with a height of 108.545 meter transmission tower. Of the two types of transmission towers will be analyzed against lightning strikes of lightning performance of each of the transmission tower. 500 kV transmission line is expected to supply electrical energy and increase the reliability of the electricity system in Sumatra area which is an area with electrical energy demand is high enough.
format Theses
author JUNAIDI (NIM : 23214099), ANDI
spellingShingle JUNAIDI (NIM : 23214099), ANDI
LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
author_facet JUNAIDI (NIM : 23214099), ANDI
author_sort JUNAIDI (NIM : 23214099), ANDI
title LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
title_short LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
title_full LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
title_fullStr LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
title_full_unstemmed LIGHTNING PERFORMANCE ANALYSIS OF EXTRA HIGH VOLTAGE 500 KV 2 CIRCUITS AND 4 CIRCUITS
title_sort lightning performance analysis of extra high voltage 500 kv 2 circuits and 4 circuits
url https://digilib.itb.ac.id/gdl/view/21041
_version_ 1822019386783825920