THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER
The technique of radiation therapy for breast cancer that is commonly used in Indonesia is external beam radiation therapy which takes a long time. In some developed countries, a new technique known as Intra-Operative Radiation Therapy (IORT) has been introduced. This treatment delivers the radiatio...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/21134 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:21134 |
---|---|
spelling |
id-itb.:211342017-09-27T11:45:21ZTHE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER AMALIA (NIM : 10212032), ANNISA Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/21134 The technique of radiation therapy for breast cancer that is commonly used in Indonesia is external beam radiation therapy which takes a long time. In some developed countries, a new technique known as Intra-Operative Radiation Therapy (IORT) has been introduced. This treatment delivers the radiation during the surgery. Since Indonesia does not have this new machine yet, the combination between IORT applicators and the conventional head linac can be an alternative. It will reduce the effect of radiation to normal tissue. It is equipped with a shielding disc that protects the organs at risk around the target. In this study, the effect of using shielding disc to percentage depth dose (PDD) from IORT applicator in conventional head linac in phantom breast cancer would be investigate. The shielding disc has 5 cm of diameters that consisting of polymethylmethacrylate (PMMA) and aluminium. The results showed that the difference between PDD from the phantom with and without shielding disc on normal tissue was 35.29% while on the organs at risk (lungs) was 3.63%. It is still under the recommended limit, i.e. 10%. The results are relevant to the goal of radiotherapy which is to maximize the dose in the target while minimize that in normal tissue. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
The technique of radiation therapy for breast cancer that is commonly used in Indonesia is external beam radiation therapy which takes a long time. In some developed countries, a new technique known as Intra-Operative Radiation Therapy (IORT) has been introduced. This treatment delivers the radiation during the surgery. Since Indonesia does not have this new machine yet, the combination between IORT applicators and the conventional head linac can be an alternative. It will reduce the effect of radiation to normal tissue. It is equipped with a shielding disc that protects the organs at risk around the target. In this study, the effect of using shielding disc to percentage depth dose (PDD) from IORT applicator in conventional head linac in phantom breast cancer would be investigate. The shielding disc has 5 cm of diameters that consisting of polymethylmethacrylate (PMMA) and aluminium. The results showed that the difference between PDD from the phantom with and without shielding disc on normal tissue was 35.29% while on the organs at risk (lungs) was 3.63%. It is still under the recommended limit, i.e. 10%. The results are relevant to the goal of radiotherapy which is to maximize the dose in the target while minimize that in normal tissue. |
format |
Final Project |
author |
AMALIA (NIM : 10212032), ANNISA |
spellingShingle |
AMALIA (NIM : 10212032), ANNISA THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
author_facet |
AMALIA (NIM : 10212032), ANNISA |
author_sort |
AMALIA (NIM : 10212032), ANNISA |
title |
THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
title_short |
THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
title_full |
THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
title_fullStr |
THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
title_full_unstemmed |
THE EFFECTS OF USING SHIELDING DISC ON PERCENTAGE DEPTH DOSE (PDD) IN INTRA-OPERATIVE RADIATION THERAPY (IORT) FOR BREAST CANCER |
title_sort |
effects of using shielding disc on percentage depth dose (pdd) in intra-operative radiation therapy (iort) for breast cancer |
url |
https://digilib.itb.ac.id/gdl/view/21134 |
_version_ |
1822920071927824384 |