THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION

One of the radiotherapy stages is Treatment Planning System (TPS), which includes the process of margin determination to ensure that the dose is adequately delivered. This research was conducted to determine the margin between Clinnical Target Volume (CTV) and Planning Target Volume (PTV). CTV-PTV m...

Full description

Saved in:
Bibliographic Details
Main Author: NURHANIVAH (NIM : 10212071), DEVI
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/21676
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:21676
spelling id-itb.:216762017-09-27T11:45:22ZTHE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION NURHANIVAH (NIM : 10212071), DEVI Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/21676 One of the radiotherapy stages is Treatment Planning System (TPS), which includes the process of margin determination to ensure that the dose is adequately delivered. This research was conducted to determine the margin between Clinnical Target Volume (CTV) and Planning Target Volume (PTV). CTV-PTV margin is the area that is likely to change due to the uncertainty of the geometry, which includes systematic and random deviations. Several hospitals use 1 cm of CTV-PTV margin without any calculations. Therefore, this study was aimed to investigate CTV-PTV margin influenced by the number and the direction of electron beams. The results would be used to make the dose distribution using finite difference method and dose calculation. This study used one to four radiation angles which were arranged in opposite direction and arbitrary direction. The results showed that the range of CTV-PTV margin was 0.01-0.47 cm and the CTV-PTV margin that was generated from the three beams direction was better than the others because it received 100% dose, while the dose recommended by ICRU 50 was about 90-107%. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description One of the radiotherapy stages is Treatment Planning System (TPS), which includes the process of margin determination to ensure that the dose is adequately delivered. This research was conducted to determine the margin between Clinnical Target Volume (CTV) and Planning Target Volume (PTV). CTV-PTV margin is the area that is likely to change due to the uncertainty of the geometry, which includes systematic and random deviations. Several hospitals use 1 cm of CTV-PTV margin without any calculations. Therefore, this study was aimed to investigate CTV-PTV margin influenced by the number and the direction of electron beams. The results would be used to make the dose distribution using finite difference method and dose calculation. This study used one to four radiation angles which were arranged in opposite direction and arbitrary direction. The results showed that the range of CTV-PTV margin was 0.01-0.47 cm and the CTV-PTV margin that was generated from the three beams direction was better than the others because it received 100% dose, while the dose recommended by ICRU 50 was about 90-107%.
format Final Project
author NURHANIVAH (NIM : 10212071), DEVI
spellingShingle NURHANIVAH (NIM : 10212071), DEVI
THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
author_facet NURHANIVAH (NIM : 10212071), DEVI
author_sort NURHANIVAH (NIM : 10212071), DEVI
title THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
title_short THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
title_full THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
title_fullStr THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
title_full_unstemmed THE INFLUENCE OF AMOUNT AND BEAM DIRECTION BETWEEN CLINICAL TARGET VOLUME (CTV) AND PLANNING TARGET VOLUME (PTV) OF MARGIN DETERMINATION
title_sort influence of amount and beam direction between clinical target volume (ctv) and planning target volume (ptv) of margin determination
url https://digilib.itb.ac.id/gdl/view/21676
_version_ 1822920251765948416