DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ
In this research has been carried out the design and development of instruments lock-in amplifier based software (virtual-LIA). Virtual-LIA designed using Vernier sensorDAQ as data acquisition and LabVIEW 2011 software as the media making the program. The design of virtual-LIA based on the working p...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/22911 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:22911 |
---|---|
spelling |
id-itb.:229112017-09-27T14:41:05ZDESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ RATRI PRASTIKA (NIM: 20214044), LINTANG Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/22911 In this research has been carried out the design and development of instruments lock-in amplifier based software (virtual-LIA). Virtual-LIA designed using Vernier sensorDAQ as data acquisition and LabVIEW 2011 software as the media making the program. The design of virtual-LIA based on the working principle of mathematical operations of LIA. The type of the virtual-LIA is a single phase with the external reference signal processing capabilities. The test is done in three ways that are: testing the program of virtual-LIA by processing a periodic signal from the signal generator in LabVIEW, test the accuracy of the reading analog input terminal Vernier SensorDAQ by processing a periodic signal of a hardware signal generator, and use the virtual-LIA for the real measurement on the experiment voltage divider circuit and the light transmission experiment. The percentage of the measurement accuracy in simulation test show the value of 98% of the simulation without noise and 96.3% for the simulation with noise. The percentage of the measurement accuracy of the test results using a signal generator indicates the value of 96%. The percentage of the measurement accuracy of the test results in the real experiments that show the value of 94% for the experiment simple voltage divider circuit, 99,14% for experiment of mica’s transmission, and 96,4% for transmission of formazin polymer suspension experiment. Overall the percentage of virtual-LIA accuracy of the measurements that have been developed in this research has reached 96,64%. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
In this research has been carried out the design and development of instruments lock-in amplifier based software (virtual-LIA). Virtual-LIA designed using Vernier sensorDAQ as data acquisition and LabVIEW 2011 software as the media making the program. The design of virtual-LIA based on the working principle of mathematical operations of LIA. The type of the virtual-LIA is a single phase with the external reference signal processing capabilities. The test is done in three ways that are: testing the program of virtual-LIA by processing a periodic signal from the signal generator in LabVIEW, test the accuracy of the reading analog input terminal Vernier SensorDAQ by processing a periodic signal of a hardware signal generator, and use the virtual-LIA for the real measurement on the experiment voltage divider circuit and the light transmission experiment. The percentage of the measurement accuracy in simulation test show the value of 98% of the simulation without noise and 96.3% for the simulation with noise. The percentage of the measurement accuracy of the test results using a signal generator indicates the value of 96%. The percentage of the measurement accuracy of the test results in the real experiments that show the value of 94% for the experiment simple voltage divider circuit, 99,14% for experiment of mica’s transmission, and 96,4% for transmission of formazin polymer suspension experiment. Overall the percentage of virtual-LIA accuracy of the measurements that have been developed in this research has reached 96,64%. |
format |
Theses |
author |
RATRI PRASTIKA (NIM: 20214044), LINTANG |
spellingShingle |
RATRI PRASTIKA (NIM: 20214044), LINTANG DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
author_facet |
RATRI PRASTIKA (NIM: 20214044), LINTANG |
author_sort |
RATRI PRASTIKA (NIM: 20214044), LINTANG |
title |
DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
title_short |
DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
title_full |
DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
title_fullStr |
DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
title_full_unstemmed |
DESIGN AND DEVELOPMENT OF THE SINGLE PHASE VIRTUAL LOCK-IN AMPLIFIER WITH EXTERNAL REFERENCE BASED ON LABVIEW AND VERNIER SENSOR DAQ |
title_sort |
design and development of the single phase virtual lock-in amplifier with external reference based on labview and vernier sensor daq |
url |
https://digilib.itb.ac.id/gdl/view/22911 |
_version_ |
1822920699097907200 |