DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD

Nowdays, there is no denying that almost all buildings need to be conditioned for the occupants to feel comfortable. One of the central cooling systems is known as chilled water system which uses chiller to cool the circulated water that conditioned the air in the room. <br /> <br /> &...

Full description

Saved in:
Bibliographic Details
Main Author: ASIDO MAULIATE S (NIM : 13113033), RUBEN
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/24119
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:24119
spelling id-itb.:241192017-09-27T10:41:06ZDETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD ASIDO MAULIATE S (NIM : 13113033), RUBEN Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/24119 Nowdays, there is no denying that almost all buildings need to be conditioned for the occupants to feel comfortable. One of the central cooling systems is known as chilled water system which uses chiller to cool the circulated water that conditioned the air in the room. <br /> <br /> <br /> Designers must choose the chiller wisely. They sometimes misunderstood that chillers only operate in full-load conditions where in fact, most chillers are now have variable speed motors to adjust with the loads. So, they tend to choose chillers based only on full-load ratings despite a chiller have different ratings on different load profiles. This differences may result in a more expensive annual energy cost. <br /> <br /> <br /> The main goal of this research is to develop an equation to provide designers not only with chiller full-load design efficiency, but also with chiller part-load efficiency. The equation to obtain part-load efficiency in certain local weather condition is called Non-standard Part Load Value (NPLV). <br /> <br /> <br /> In this research project, the NPLV equation of several cities in Indonesia (Bandung, Pontianak, and Kupang) will be obtained by Degree-Hours Method and Radiant Time Series cooling load calculations. The results were compared to actual load profile of a chiller that was operated at Building X. At the end, there is a recommendation to use Air Cooled Centrifugal Chiller by Thermal Care for the most efficient type of chiller to be operated in all three cities, based on their NPLV values. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Nowdays, there is no denying that almost all buildings need to be conditioned for the occupants to feel comfortable. One of the central cooling systems is known as chilled water system which uses chiller to cool the circulated water that conditioned the air in the room. <br /> <br /> <br /> Designers must choose the chiller wisely. They sometimes misunderstood that chillers only operate in full-load conditions where in fact, most chillers are now have variable speed motors to adjust with the loads. So, they tend to choose chillers based only on full-load ratings despite a chiller have different ratings on different load profiles. This differences may result in a more expensive annual energy cost. <br /> <br /> <br /> The main goal of this research is to develop an equation to provide designers not only with chiller full-load design efficiency, but also with chiller part-load efficiency. The equation to obtain part-load efficiency in certain local weather condition is called Non-standard Part Load Value (NPLV). <br /> <br /> <br /> In this research project, the NPLV equation of several cities in Indonesia (Bandung, Pontianak, and Kupang) will be obtained by Degree-Hours Method and Radiant Time Series cooling load calculations. The results were compared to actual load profile of a chiller that was operated at Building X. At the end, there is a recommendation to use Air Cooled Centrifugal Chiller by Thermal Care for the most efficient type of chiller to be operated in all three cities, based on their NPLV values.
format Final Project
author ASIDO MAULIATE S (NIM : 13113033), RUBEN
spellingShingle ASIDO MAULIATE S (NIM : 13113033), RUBEN
DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
author_facet ASIDO MAULIATE S (NIM : 13113033), RUBEN
author_sort ASIDO MAULIATE S (NIM : 13113033), RUBEN
title DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
title_short DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
title_full DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
title_fullStr DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
title_full_unstemmed DETERMINATION OF NPLV COEFFICIENT ON CITIES OF PONTIANAK, KUPANG, AND BANDUNG BY DEGREE HOURS METHOD AND RTS COOLING LOAD CALCULATIONS METHOD
title_sort determination of nplv coefficient on cities of pontianak, kupang, and bandung by degree hours method and rts cooling load calculations method
url https://digilib.itb.ac.id/gdl/view/24119
_version_ 1822020299754831872