MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE
Ranitidine is widely used for gastric or "maag" treatment. Ranitidine inhibits the action of histamine and reduces gastric acid secretion. Determination of ranitidine requires a simple, accurate, sensitive, and low cost method. In this study, we developed carbon paste electrodes (CPE) modi...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/24136 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:24136 |
---|---|
spelling |
id-itb.:241362017-09-27T15:39:48ZMOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE (NIM : 20513066), RUSTIANINGSIH Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/24136 Ranitidine is widely used for gastric or "maag" treatment. Ranitidine inhibits the action of histamine and reduces gastric acid secretion. Determination of ranitidine requires a simple, accurate, sensitive, and low cost method. In this study, we developed carbon paste electrodes (CPE) modified with molecularly imprinted poly(methyl red) as working electrode for voltammetric determination of ranitidine. Methyl red was electropolymerized on the surface of CPE using cyclic <br /> <br /> <br /> voltammetry technique from solution containing 2 mM methyl red, 1 mM ranitidine and phosphate buffer pH 7. In this process, five cycles of electrode potential was applied in the range of 0.2 V - 1.5 V with scan rate of 100 mV/s. The calibration curve was linearin the concentration range of 0.01 mM - 1.00 mM with a detection limit of 7.96 μM. Interference study showed that ranitidine determinations were not interfered by amoxicillin, ascorbic acid, glycine and paracetamol. Determination of ranitidine in drug samples showed good accuracy with percent recovery between 97,29% - 103,00%. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Ranitidine is widely used for gastric or "maag" treatment. Ranitidine inhibits the action of histamine and reduces gastric acid secretion. Determination of ranitidine requires a simple, accurate, sensitive, and low cost method. In this study, we developed carbon paste electrodes (CPE) modified with molecularly imprinted poly(methyl red) as working electrode for voltammetric determination of ranitidine. Methyl red was electropolymerized on the surface of CPE using cyclic <br />
<br />
<br />
voltammetry technique from solution containing 2 mM methyl red, 1 mM ranitidine and phosphate buffer pH 7. In this process, five cycles of electrode potential was applied in the range of 0.2 V - 1.5 V with scan rate of 100 mV/s. The calibration curve was linearin the concentration range of 0.01 mM - 1.00 mM with a detection limit of 7.96 μM. Interference study showed that ranitidine determinations were not interfered by amoxicillin, ascorbic acid, glycine and paracetamol. Determination of ranitidine in drug samples showed good accuracy with percent recovery between 97,29% - 103,00%. |
format |
Theses |
author |
(NIM : 20513066), RUSTIANINGSIH |
spellingShingle |
(NIM : 20513066), RUSTIANINGSIH MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
author_facet |
(NIM : 20513066), RUSTIANINGSIH |
author_sort |
(NIM : 20513066), RUSTIANINGSIH |
title |
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
title_short |
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
title_full |
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
title_fullStr |
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
title_full_unstemmed |
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF RANITIDINE |
title_sort |
molecularly imprinted poly(methyl red) modified carbon paste electrode for voltammetric determination of ranitidine |
url |
https://digilib.itb.ac.id/gdl/view/24136 |
_version_ |
1822921131158405120 |