CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL
<p align="justify">In this research, carbon paste electrode modified with carbon nanotube and molecularly immprinted poly (3-aminophenol) (CPE-CNT-MIP) for voltammetric determination of paracetamol had been succesfuly developed. The modified electrode was made by dispersing CNT (2 mg...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/24925 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:24925 |
---|---|
spelling |
id-itb.:249252018-10-10T08:55:46ZCARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL ABRAHAM MORA (NIM: 10512014), Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/24925 <p align="justify">In this research, carbon paste electrode modified with carbon nanotube and molecularly immprinted poly (3-aminophenol) (CPE-CNT-MIP) for voltammetric determination of paracetamol had been succesfuly developed. The modified electrode was made by dispersing CNT (2 mg/mL) on the surface of CPE followed by electropolymerization of 3-aminophenol using 15 cycle of potential in the potential range of -0.2 V - 1.2 V with scan rate of 100 mV/s in HClO4 0.1 M solution containing 3-aminophenol and paracetamol. To produce MIP, paracetamol was removed from polymer matrix with 10 cycle of potential in the same potential range in HClO4 0.1 M solution. Paracetamol measurements were conducted with square wave voltammetry technique. Repeated measurement of paracetamol 0.1 mM resulted in RSD of 5.70% (n = 20). The best calibration curve was found in the concentration range of 6 x 10-4 mM - 1 x 10-1 mM (r2 = 0.9965) and a detection limit of 0,480 μM. Determination of paracetamol in 3 samples of commercial drugs resulted in percent recovery between 99.77% and 104.88%; The results was in accordance with those of spectrophotometric.<p align="justify"> text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
<p align="justify">In this research, carbon paste electrode modified with carbon nanotube and molecularly immprinted poly (3-aminophenol) (CPE-CNT-MIP) for voltammetric determination of paracetamol had been succesfuly developed. The modified electrode was made by dispersing CNT (2 mg/mL) on the surface of CPE followed by electropolymerization of 3-aminophenol using 15 cycle of potential in the potential range of -0.2 V - 1.2 V with scan rate of 100 mV/s in HClO4 0.1 M solution containing 3-aminophenol and paracetamol. To produce MIP, paracetamol was removed from polymer matrix with 10 cycle of potential in the same potential range in HClO4 0.1 M solution. Paracetamol measurements were conducted with square wave voltammetry technique. Repeated measurement of paracetamol 0.1 mM resulted in RSD of 5.70% (n = 20). The best calibration curve was found in the concentration range of 6 x 10-4 mM - 1 x 10-1 mM (r2 = 0.9965) and a detection limit of 0,480 μM. Determination of paracetamol in 3 samples of commercial drugs resulted in percent recovery between 99.77% and 104.88%; The results was in accordance with those of spectrophotometric.<p align="justify"> |
format |
Final Project |
author |
ABRAHAM MORA (NIM: 10512014), |
spellingShingle |
ABRAHAM MORA (NIM: 10512014), CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
author_facet |
ABRAHAM MORA (NIM: 10512014), |
author_sort |
ABRAHAM MORA (NIM: 10512014), |
title |
CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
title_short |
CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
title_full |
CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
title_fullStr |
CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
title_full_unstemmed |
CARBON PASTE ELECTRODE MODIFIED BY CARBON NANOTUBES AND MOLECULARLY IMPRINTED POLY (3-AMINOPHENOL) FOR VOLTAMMETRIC DETERMINATION OF PARACETAMOL |
title_sort |
carbon paste electrode modified by carbon nanotubes and molecularly imprinted poly (3-aminophenol) for voltammetric determination of paracetamol |
url |
https://digilib.itb.ac.id/gdl/view/24925 |
_version_ |
1821844823967006720 |