STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY

<p align="justify">Flood events occur every year in the Tangerang City, with an inundation level of 50cm to 2.40 meters, inundation level has exceeded the inundation criteria permitted in the smart city policy of Tangerang City, ie the depth does not exceed 10 cm and the inundati...

Full description

Saved in:
Bibliographic Details
Main Author: - NIM : 95015309 , BERIANSYAH
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/26075
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:26075
spelling id-itb.:260752018-09-27T14:50:19ZSTUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY - NIM : 95015309 , BERIANSYAH Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/26075 <p align="justify">Flood events occur every year in the Tangerang City, with an inundation level of 50cm to 2.40 meters, inundation level has exceeded the inundation criteria permitted in the smart city policy of Tangerang City, ie the depth does not exceed 10 cm and the inundation period does not exceed 1 hour. The main objective of this study is to obtain a flood control model that meets the inundation criteria in the smart city policy and is able to provide an overview of the flood control of Tangerang City. This research consists of; 1) Analyze the design flood discharge. 2) 1-dimensional and 2-dimensional hydrodynamic modeling with Mike 2017 software. 3) Analysis of flood occurrence in Tangerang City against 16 scenarios including a combination of variations in planned flood discharge from upstream and influences of 5, 10, 25, 50 years of return period local rain. 4) Analysis of increase in river section capacity and optimization of capacity and operating pattern of flood pumps. <br /> <br /> <br /> The results of the 1-dimensional simulation show that the inundation occurs due to the existing capacity of the river crossing in the Cirarab, Cisadane and Angke watersheds unable to accommodate flood discharge from the upstream of the river, as well as the optimal capacity & pattern of operation of the flood pump and detention pond in overcoming runoff due to local rainfall in the City area Tangerang. From the results of the 2-dimensional simulation simulation with mike flood, flood areas inundated the settlement area with an area reaching 46.68% of the total inundation area and the rest were industrial areas, grasslands, plantations, shrubs and fields. inundation mitigation is overcome by raising embankment to overcome runoff from upstream, increasing the capacity of flood pumps and creating detention pools for inundation due to local rainfall in the Tangerang City area. <p align="justify"> <br /> <br /> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <p align="justify">Flood events occur every year in the Tangerang City, with an inundation level of 50cm to 2.40 meters, inundation level has exceeded the inundation criteria permitted in the smart city policy of Tangerang City, ie the depth does not exceed 10 cm and the inundation period does not exceed 1 hour. The main objective of this study is to obtain a flood control model that meets the inundation criteria in the smart city policy and is able to provide an overview of the flood control of Tangerang City. This research consists of; 1) Analyze the design flood discharge. 2) 1-dimensional and 2-dimensional hydrodynamic modeling with Mike 2017 software. 3) Analysis of flood occurrence in Tangerang City against 16 scenarios including a combination of variations in planned flood discharge from upstream and influences of 5, 10, 25, 50 years of return period local rain. 4) Analysis of increase in river section capacity and optimization of capacity and operating pattern of flood pumps. <br /> <br /> <br /> The results of the 1-dimensional simulation show that the inundation occurs due to the existing capacity of the river crossing in the Cirarab, Cisadane and Angke watersheds unable to accommodate flood discharge from the upstream of the river, as well as the optimal capacity & pattern of operation of the flood pump and detention pond in overcoming runoff due to local rainfall in the City area Tangerang. From the results of the 2-dimensional simulation simulation with mike flood, flood areas inundated the settlement area with an area reaching 46.68% of the total inundation area and the rest were industrial areas, grasslands, plantations, shrubs and fields. inundation mitigation is overcome by raising embankment to overcome runoff from upstream, increasing the capacity of flood pumps and creating detention pools for inundation due to local rainfall in the Tangerang City area. <p align="justify"> <br /> <br />
format Theses
author - NIM : 95015309 , BERIANSYAH
spellingShingle - NIM : 95015309 , BERIANSYAH
STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
author_facet - NIM : 95015309 , BERIANSYAH
author_sort - NIM : 95015309 , BERIANSYAH
title STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
title_short STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
title_full STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
title_fullStr STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
title_full_unstemmed STUDY OF FLOOD CONTROL MODELS TO SUPPORT SMART CITY POLICY TANGERANG CITY
title_sort study of flood control models to support smart city policy tangerang city
url https://digilib.itb.ac.id/gdl/view/26075
_version_ 1822921777282547712