ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS

The design of high-rise building has issues in excessive lateral deformation and serviceability. The common system that is used such as coupled shearwall is no longer capable of overcome these problems for high-rise structure. In order to overcome these problem, outrigger and belttruss system is use...

Full description

Saved in:
Bibliographic Details
Main Author: KASLAN , DAVY
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/26418
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:26418
spelling id-itb.:264182018-03-13T08:50:50ZANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS KASLAN , DAVY Teknik sipil Indonesia Theses INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/26418 The design of high-rise building has issues in excessive lateral deformation and serviceability. The common system that is used such as coupled shearwall is no longer capable of overcome these problems for high-rise structure. In order to overcome these problem, outrigger and belttruss system is used. Commonly in coupled shearwall system, coupling beam is the main dissipator element. This research is addressed to get information of plastification hierarchy when outrigger and belttruss is added to the coupled shearwall system, and the effective L/H ratio of coupling beam. <br /> <br /> Based on nonlinear analysis which is consist of pushover analysis and time history analysis, the performance of model that is use the L/H ratio of 4 and SMF beam reinforcement is worse than model with L/H ratio of 2 and 3. This is caused by the excessive rotation of coupling beam up to 0.65 CP. Meanwhile, for model with L/H ratio of 2 and 3 with diagonal reinforcement and L/H=3 with SMF beam reinforcement have similar performance and behavior but better than model with ratio L/H=4. Besides, plastification hierarchy, for L/H=2 and 3, shift to main beam, base shearwall, shearwall at outrigger location, and mega column. So, the most effective L/H ratio of coupling beam for outrigger and belttruss system based on this research is 3 and with the use of SMF beam reinforcement (without diagonal reinforcement). text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
KASLAN , DAVY
ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
description The design of high-rise building has issues in excessive lateral deformation and serviceability. The common system that is used such as coupled shearwall is no longer capable of overcome these problems for high-rise structure. In order to overcome these problem, outrigger and belttruss system is used. Commonly in coupled shearwall system, coupling beam is the main dissipator element. This research is addressed to get information of plastification hierarchy when outrigger and belttruss is added to the coupled shearwall system, and the effective L/H ratio of coupling beam. <br /> <br /> Based on nonlinear analysis which is consist of pushover analysis and time history analysis, the performance of model that is use the L/H ratio of 4 and SMF beam reinforcement is worse than model with L/H ratio of 2 and 3. This is caused by the excessive rotation of coupling beam up to 0.65 CP. Meanwhile, for model with L/H ratio of 2 and 3 with diagonal reinforcement and L/H=3 with SMF beam reinforcement have similar performance and behavior but better than model with ratio L/H=4. Besides, plastification hierarchy, for L/H=2 and 3, shift to main beam, base shearwall, shearwall at outrigger location, and mega column. So, the most effective L/H ratio of coupling beam for outrigger and belttruss system based on this research is 3 and with the use of SMF beam reinforcement (without diagonal reinforcement).
format Theses
author KASLAN , DAVY
author_facet KASLAN , DAVY
author_sort KASLAN , DAVY
title ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
title_short ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
title_full ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
title_fullStr ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
title_full_unstemmed ANALYSIS OF THE EFFECTIVITY OF COUPLING BEAM ON HIGH RISE-BUILDING STRUCTURE USING OUTRIGGER AND BELTTRUSS
title_sort analysis of the effectivity of coupling beam on high rise-building structure using outrigger and belttruss
url https://digilib.itb.ac.id/gdl/view/26418
_version_ 1822021006807531520