#TITLE_ALTERNATIVE#
Ambient air quality monitoring is performed to monitor pollutants concentration levels in atmosphere that might have harmful effect to human health. Based on PP no. 41 tahun 1999, some pollutants such as SO2, NOx, and PM10 required to be measured for 24 hours. However, the full measurement often can...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/27471 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:27471 |
---|---|
spelling |
id-itb.:274712018-03-09T16:32:54Z#TITLE_ALTERNATIVE# SURYA MARTEDA (NIM : 15309069), GEDE Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/27471 Ambient air quality monitoring is performed to monitor pollutants concentration levels in atmosphere that might have harmful effect to human health. Based on PP no. 41 tahun 1999, some pollutants such as SO2, NOx, and PM10 required to be measured for 24 hours. However, the full measurement often cannot be done due to weather condition or technical problems. The objective of this research is to identify the most significant time duration attributed to urban activity that affect diurnal concentration of SO2, NOx, and PM10. The statistical models developed in this study were used for estimating 24-hour concentrations from less than 24-hour measurement at each type of land-use in the area of DKI Jakarta. At the early stages, the daily fluctuation of SO2, NOx, and PM10 in each type of land-use were identified. Then, the concentration of these pollutants of various durations (12, 16, 18, 20, and 24 hours) which were expected to represent urban activity within the 24-hours average concentration were analyzed using paired-t test and scatter plot. The plots described the ratio of measurement duration and 24-hour (T/T24) versus the ratio of associated concentration and 24-hours concentration (C/C24). It is concluded that the model can reasonably predict the 24-hour average concentration with 20-hours minimum measurement provide the best estimation (R2 average is 0.9). The models were validated against manual active concentration. The validation result shows on average of 5.43% (0.168 μg/m3 and 2,974 μg/m3) ranging between 0,6% (0.52 μg/m3 ) to10,9% (2,965 ppb). text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Ambient air quality monitoring is performed to monitor pollutants concentration levels in atmosphere that might have harmful effect to human health. Based on PP no. 41 tahun 1999, some pollutants such as SO2, NOx, and PM10 required to be measured for 24 hours. However, the full measurement often cannot be done due to weather condition or technical problems. The objective of this research is to identify the most significant time duration attributed to urban activity that affect diurnal concentration of SO2, NOx, and PM10. The statistical models developed in this study were used for estimating 24-hour concentrations from less than 24-hour measurement at each type of land-use in the area of DKI Jakarta. At the early stages, the daily fluctuation of SO2, NOx, and PM10 in each type of land-use were identified. Then, the concentration of these pollutants of various durations (12, 16, 18, 20, and 24 hours) which were expected to represent urban activity within the 24-hours average concentration were analyzed using paired-t test and scatter plot. The plots described the ratio of measurement duration and 24-hour (T/T24) versus the ratio of associated concentration and 24-hours concentration (C/C24). It is concluded that the model can reasonably predict the 24-hour average concentration with 20-hours minimum measurement provide the best estimation (R2 average is 0.9). The models were validated against manual active concentration. The validation result shows on average of 5.43% (0.168 μg/m3 and 2,974 μg/m3) ranging between 0,6% (0.52 μg/m3 ) to10,9% (2,965 ppb). |
format |
Final Project |
author |
SURYA MARTEDA (NIM : 15309069), GEDE |
spellingShingle |
SURYA MARTEDA (NIM : 15309069), GEDE #TITLE_ALTERNATIVE# |
author_facet |
SURYA MARTEDA (NIM : 15309069), GEDE |
author_sort |
SURYA MARTEDA (NIM : 15309069), GEDE |
title |
#TITLE_ALTERNATIVE# |
title_short |
#TITLE_ALTERNATIVE# |
title_full |
#TITLE_ALTERNATIVE# |
title_fullStr |
#TITLE_ALTERNATIVE# |
title_full_unstemmed |
#TITLE_ALTERNATIVE# |
title_sort |
#title_alternative# |
url |
https://digilib.itb.ac.id/gdl/view/27471 |
_version_ |