Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model

Geothermal energy is an energy that come from magma in center of the <br /> <br /> <br /> <br /> earth. This energy is clean and has high sustainability. Before the utilization <br /> <br /> <br /> <br /> from a geothermal well begin, the well...

Full description

Saved in:
Bibliographic Details
Main Author: Yoan Sandy Utama 13114036, Gita
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/27555
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:27555
spelling id-itb.:275552018-09-21T15:28:36ZValidation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model Yoan Sandy Utama 13114036, Gita Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/27555 Geothermal energy is an energy that come from magma in center of the <br /> <br /> <br /> <br /> earth. This energy is clean and has high sustainability. Before the utilization <br /> <br /> <br /> <br /> from a geothermal well begin, the well itself will be production tested, so the <br /> <br /> <br /> <br /> properness of the well can be known. One method that is commonly used is <br /> <br /> <br /> <br /> discharge test. The purpose in to validate estimate result from discharge teset <br /> <br /> <br /> <br /> equation with data from sensor and also remodelling the parameter for <br /> <br /> <br /> <br /> dischargte test equation. <br /> <br /> <br /> <br /> In this research HEM is used for determine the assumption used. That is <br /> <br /> <br /> <br /> because with that assumption fluid's parameter is easy to find. First there will <br /> <br /> <br /> <br /> be a validation that compare data from sensor and from discharge test equation. <br /> <br /> <br /> <br /> Then after we find the average relative error of the equation for the sensor, we <br /> <br /> <br /> <br /> will evaluate the parameter used for that discharge test equation before we reevaluate <br /> <br /> <br /> <br /> to make new equation. <br /> <br /> <br /> <br /> From the validation average relative error for numeric equation is <br /> <br /> <br /> <br /> 201,98%, Russell James equation is 4,18% and Russell James equation with <br /> <br /> <br /> <br /> HEM modelling is 10,56% text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Geothermal energy is an energy that come from magma in center of the <br /> <br /> <br /> <br /> earth. This energy is clean and has high sustainability. Before the utilization <br /> <br /> <br /> <br /> from a geothermal well begin, the well itself will be production tested, so the <br /> <br /> <br /> <br /> properness of the well can be known. One method that is commonly used is <br /> <br /> <br /> <br /> discharge test. The purpose in to validate estimate result from discharge teset <br /> <br /> <br /> <br /> equation with data from sensor and also remodelling the parameter for <br /> <br /> <br /> <br /> dischargte test equation. <br /> <br /> <br /> <br /> In this research HEM is used for determine the assumption used. That is <br /> <br /> <br /> <br /> because with that assumption fluid's parameter is easy to find. First there will <br /> <br /> <br /> <br /> be a validation that compare data from sensor and from discharge test equation. <br /> <br /> <br /> <br /> Then after we find the average relative error of the equation for the sensor, we <br /> <br /> <br /> <br /> will evaluate the parameter used for that discharge test equation before we reevaluate <br /> <br /> <br /> <br /> to make new equation. <br /> <br /> <br /> <br /> From the validation average relative error for numeric equation is <br /> <br /> <br /> <br /> 201,98%, Russell James equation is 4,18% and Russell James equation with <br /> <br /> <br /> <br /> HEM modelling is 10,56%
format Final Project
author Yoan Sandy Utama 13114036, Gita
spellingShingle Yoan Sandy Utama 13114036, Gita
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
author_facet Yoan Sandy Utama 13114036, Gita
author_sort Yoan Sandy Utama 13114036, Gita
title Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
title_short Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
title_full Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
title_fullStr Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
title_full_unstemmed Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
title_sort validation and parameter evaluation for two- phase discharge test equation with hem analytic model
url https://digilib.itb.ac.id/gdl/view/27555
_version_ 1822922288171843584