Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model
Geothermal energy is an energy that come from magma in center of the <br /> <br /> <br /> <br /> earth. This energy is clean and has high sustainability. Before the utilization <br /> <br /> <br /> <br /> from a geothermal well begin, the well...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/27555 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:27555 |
---|---|
spelling |
id-itb.:275552018-09-21T15:28:36ZValidation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model Yoan Sandy Utama 13114036, Gita Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/27555 Geothermal energy is an energy that come from magma in center of the <br /> <br /> <br /> <br /> earth. This energy is clean and has high sustainability. Before the utilization <br /> <br /> <br /> <br /> from a geothermal well begin, the well itself will be production tested, so the <br /> <br /> <br /> <br /> properness of the well can be known. One method that is commonly used is <br /> <br /> <br /> <br /> discharge test. The purpose in to validate estimate result from discharge teset <br /> <br /> <br /> <br /> equation with data from sensor and also remodelling the parameter for <br /> <br /> <br /> <br /> dischargte test equation. <br /> <br /> <br /> <br /> In this research HEM is used for determine the assumption used. That is <br /> <br /> <br /> <br /> because with that assumption fluid's parameter is easy to find. First there will <br /> <br /> <br /> <br /> be a validation that compare data from sensor and from discharge test equation. <br /> <br /> <br /> <br /> Then after we find the average relative error of the equation for the sensor, we <br /> <br /> <br /> <br /> will evaluate the parameter used for that discharge test equation before we reevaluate <br /> <br /> <br /> <br /> to make new equation. <br /> <br /> <br /> <br /> From the validation average relative error for numeric equation is <br /> <br /> <br /> <br /> 201,98%, Russell James equation is 4,18% and Russell James equation with <br /> <br /> <br /> <br /> HEM modelling is 10,56% text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
Geothermal energy is an energy that come from magma in center of the <br />
<br />
<br />
<br />
earth. This energy is clean and has high sustainability. Before the utilization <br />
<br />
<br />
<br />
from a geothermal well begin, the well itself will be production tested, so the <br />
<br />
<br />
<br />
properness of the well can be known. One method that is commonly used is <br />
<br />
<br />
<br />
discharge test. The purpose in to validate estimate result from discharge teset <br />
<br />
<br />
<br />
equation with data from sensor and also remodelling the parameter for <br />
<br />
<br />
<br />
dischargte test equation. <br />
<br />
<br />
<br />
In this research HEM is used for determine the assumption used. That is <br />
<br />
<br />
<br />
because with that assumption fluid's parameter is easy to find. First there will <br />
<br />
<br />
<br />
be a validation that compare data from sensor and from discharge test equation. <br />
<br />
<br />
<br />
Then after we find the average relative error of the equation for the sensor, we <br />
<br />
<br />
<br />
will evaluate the parameter used for that discharge test equation before we reevaluate <br />
<br />
<br />
<br />
to make new equation. <br />
<br />
<br />
<br />
From the validation average relative error for numeric equation is <br />
<br />
<br />
<br />
201,98%, Russell James equation is 4,18% and Russell James equation with <br />
<br />
<br />
<br />
HEM modelling is 10,56% |
format |
Final Project |
author |
Yoan Sandy Utama 13114036, Gita |
spellingShingle |
Yoan Sandy Utama 13114036, Gita Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
author_facet |
Yoan Sandy Utama 13114036, Gita |
author_sort |
Yoan Sandy Utama 13114036, Gita |
title |
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
title_short |
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
title_full |
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
title_fullStr |
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
title_full_unstemmed |
Validation and Parameter Evaluation for Two- Phase Discharge Test Equation with HEM Analytic Model |
title_sort |
validation and parameter evaluation for two- phase discharge test equation with hem analytic model |
url |
https://digilib.itb.ac.id/gdl/view/27555 |
_version_ |
1822922288171843584 |