An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source

<p align="justify"> <br /> <br /> Cloth drying is one of the most important daily activities and it is a sector that consumes large amount of energy. Cloth drying has become constricted to indoor drying over time due to various factors. This method is usually ineffective...

Full description

Saved in:
Bibliographic Details
Main Author: DANANG PRIAMBODO (NIM : 13114063), MUHAMAD
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/29072
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:29072
spelling id-itb.:290722018-06-29T14:55:19ZAn Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source DANANG PRIAMBODO (NIM : 13114063), MUHAMAD Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/29072 <p align="justify"> <br /> <br /> Cloth drying is one of the most important daily activities and it is a sector that consumes large amount of energy. Cloth drying has become constricted to indoor drying over time due to various factors. This method is usually ineffective and takes much longer. On the other hand, a recent evaluation in the UK revealed that 63% of waste energy is a low temperature heat. Now, a special drying room that is attached to an air conditioner condenser can be designed to utilize its low temperature heat. The purpose of this research is to know the influence of temperature, air rate, and hanger width to drying rate and drying time, to know the influence of relative humidity to equilibrium moisture content and to determine the optimum condition of drying. <br /> <br /> This experiment was done by simulating cloth drying in a duct, using a fan and an electric heater. With a two-level factorial design, the selected conditions are temperatures at 26 & 40 oC, drying air rates at 0.33 & 1 m/s, and hanger widths at 1 & 5 cm. There is an additional experiment with conditions at 33 oC, 0.67 m/s, and 3 cm. From this experiment, the conclusions are the wider the hanger width, the higher the drying air rate, and the higher the temperature, the greater the drying rate would be. Temperature has the biggest effect. Nevertheless, there is an interaction between two variables, in which an interaction between temperature rise and drying air rate rise would significantly increase the constant drying rate, whereas, any interaction with hanger width rise would decrease it. The reduction of the drying air’s relative humidity could generally decrease the equilibrium moisture of the cloth. The optimum conditions for this design were at 40 oC temperature, 1 m/s drying air rate, and 1 cm hanger width. <br /> <p align="justify"> text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description <p align="justify"> <br /> <br /> Cloth drying is one of the most important daily activities and it is a sector that consumes large amount of energy. Cloth drying has become constricted to indoor drying over time due to various factors. This method is usually ineffective and takes much longer. On the other hand, a recent evaluation in the UK revealed that 63% of waste energy is a low temperature heat. Now, a special drying room that is attached to an air conditioner condenser can be designed to utilize its low temperature heat. The purpose of this research is to know the influence of temperature, air rate, and hanger width to drying rate and drying time, to know the influence of relative humidity to equilibrium moisture content and to determine the optimum condition of drying. <br /> <br /> This experiment was done by simulating cloth drying in a duct, using a fan and an electric heater. With a two-level factorial design, the selected conditions are temperatures at 26 & 40 oC, drying air rates at 0.33 & 1 m/s, and hanger widths at 1 & 5 cm. There is an additional experiment with conditions at 33 oC, 0.67 m/s, and 3 cm. From this experiment, the conclusions are the wider the hanger width, the higher the drying air rate, and the higher the temperature, the greater the drying rate would be. Temperature has the biggest effect. Nevertheless, there is an interaction between two variables, in which an interaction between temperature rise and drying air rate rise would significantly increase the constant drying rate, whereas, any interaction with hanger width rise would decrease it. The reduction of the drying air’s relative humidity could generally decrease the equilibrium moisture of the cloth. The optimum conditions for this design were at 40 oC temperature, 1 m/s drying air rate, and 1 cm hanger width. <br /> <p align="justify">
format Final Project
author DANANG PRIAMBODO (NIM : 13114063), MUHAMAD
spellingShingle DANANG PRIAMBODO (NIM : 13114063), MUHAMAD
An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
author_facet DANANG PRIAMBODO (NIM : 13114063), MUHAMAD
author_sort DANANG PRIAMBODO (NIM : 13114063), MUHAMAD
title An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
title_short An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
title_full An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
title_fullStr An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
title_full_unstemmed An Experimental Study on Cloth Drying by Utilizing Low Temperature Heat Source
title_sort experimental study on cloth drying by utilizing low temperature heat source
url https://digilib.itb.ac.id/gdl/view/29072
_version_ 1822021927354499072