THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD

The IOERT (Intraoperative Electron-beam Radiation Therapy) method is a cancer treatment method that uses a combination of surgical techniques and radiation techniques. The IOERT method can be successfully categorized when it can be able to distribute homogeneous doses of radiation to targeted tumors...

Full description

Saved in:
Bibliographic Details
Main Author: ILHAM RAMADHAN (NIM : 10214062), NUZUL
Format: Final Project
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/29856
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:29856
spelling id-itb.:298562018-08-07T11:04:20ZTHE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD ILHAM RAMADHAN (NIM : 10214062), NUZUL Indonesia Final Project INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/29856 The IOERT (Intraoperative Electron-beam Radiation Therapy) method is a cancer treatment method that uses a combination of surgical techniques and radiation techniques. The IOERT method can be successfully categorized when it can be able to distribute homogeneous doses of radiation to targeted tumors. In this study, the optimum electron beam energy and the applicator size of the IOERT method were performed with beam symmetry and beam flatness and parameters on the 1-D dose distribution curve (PDD and dose profile) generated. This is done because the homogeneity of a beam can be measured from beam flatness and beam symmetry. Electron beam energy optimization and IOERT treatment applicator size were performed using Monte Carlo method with EGSnrc software program package. In this study the electron beam energy to be optimized is 4, 6, 8, 10, and 12 MeV, and the size of the applicator IOERT diameter to be optimized in the range of 3-10 cm. In this study also selected source files that meet the form of Gaussian distribution that represents the direction of motion and position of the electron beam with the width of FWHM set at 2 mm. Electron energy for IOERT is greater than 0.68% to 5.37% of other treatment methods. Electron beam energy and large applicator diameter sizes will cause worse heterogeneity of the beam. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The IOERT (Intraoperative Electron-beam Radiation Therapy) method is a cancer treatment method that uses a combination of surgical techniques and radiation techniques. The IOERT method can be successfully categorized when it can be able to distribute homogeneous doses of radiation to targeted tumors. In this study, the optimum electron beam energy and the applicator size of the IOERT method were performed with beam symmetry and beam flatness and parameters on the 1-D dose distribution curve (PDD and dose profile) generated. This is done because the homogeneity of a beam can be measured from beam flatness and beam symmetry. Electron beam energy optimization and IOERT treatment applicator size were performed using Monte Carlo method with EGSnrc software program package. In this study the electron beam energy to be optimized is 4, 6, 8, 10, and 12 MeV, and the size of the applicator IOERT diameter to be optimized in the range of 3-10 cm. In this study also selected source files that meet the form of Gaussian distribution that represents the direction of motion and position of the electron beam with the width of FWHM set at 2 mm. Electron energy for IOERT is greater than 0.68% to 5.37% of other treatment methods. Electron beam energy and large applicator diameter sizes will cause worse heterogeneity of the beam.
format Final Project
author ILHAM RAMADHAN (NIM : 10214062), NUZUL
spellingShingle ILHAM RAMADHAN (NIM : 10214062), NUZUL
THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
author_facet ILHAM RAMADHAN (NIM : 10214062), NUZUL
author_sort ILHAM RAMADHAN (NIM : 10214062), NUZUL
title THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
title_short THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
title_full THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
title_fullStr THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
title_full_unstemmed THE EFFECT OF CHOOSING ELECTRON BEAM ENERGY AND IOERT TREATMENT APPLICATOR SIZE ON BEAM FLATNESS AND BEAM SYMMETRY PARAMETERS BY USING MONTE CARLO METHOD
title_sort effect of choosing electron beam energy and ioert treatment applicator size on beam flatness and beam symmetry parameters by using monte carlo method
url https://digilib.itb.ac.id/gdl/view/29856
_version_ 1822923058188386304