THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING

The spatial resolution of PET imaging is not as good as other imaging techniques such as CT and MRI. One method to increase the spatial resolution of PET is to use magnetic fields. In this study, we will find the optimum magnetic field value to improve the spatial resolution of PET using 10 positron...

Full description

Saved in:
Bibliographic Details
Main Author: DEWI INDRIASARI (NIM : 10213005), YULISTIANI
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/31820
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:31820
spelling id-itb.:318202018-08-31T08:44:24ZTHE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING DEWI INDRIASARI (NIM : 10213005), YULISTIANI Fisika Indonesia Final Project FWHM, PET, positron range, spatial resolution. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/31820 The spatial resolution of PET imaging is not as good as other imaging techniques such as CT and MRI. One method to increase the spatial resolution of PET is to use magnetic fields. In this study, we will find the optimum magnetic field value to improve the spatial resolution of PET using 10 positron emitter isotopes. To calculate the positron range from each radioisotope, positron emission were simulated in the water phantom using the Geant4 Application for Tomography Emission (GATE). The results of this simulation are frequency to the positron range in the form of Gaussian distributions. From this distribution curve, FWHM analysis was carried out to determine the contribution of each radioisotope in reducing PET spatial resolution. The magnetic fields effect of 0.5 to 11.7 T on the PET system will be simulated. From the results of this simulation, the new FWHM values will be obtained and compared to the previous results. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Fisika
spellingShingle Fisika
DEWI INDRIASARI (NIM : 10213005), YULISTIANI
THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
description The spatial resolution of PET imaging is not as good as other imaging techniques such as CT and MRI. One method to increase the spatial resolution of PET is to use magnetic fields. In this study, we will find the optimum magnetic field value to improve the spatial resolution of PET using 10 positron emitter isotopes. To calculate the positron range from each radioisotope, positron emission were simulated in the water phantom using the Geant4 Application for Tomography Emission (GATE). The results of this simulation are frequency to the positron range in the form of Gaussian distributions. From this distribution curve, FWHM analysis was carried out to determine the contribution of each radioisotope in reducing PET spatial resolution. The magnetic fields effect of 0.5 to 11.7 T on the PET system will be simulated. From the results of this simulation, the new FWHM values will be obtained and compared to the previous results.
format Final Project
author DEWI INDRIASARI (NIM : 10213005), YULISTIANI
author_facet DEWI INDRIASARI (NIM : 10213005), YULISTIANI
author_sort DEWI INDRIASARI (NIM : 10213005), YULISTIANI
title THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
title_short THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
title_full THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
title_fullStr THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
title_full_unstemmed THE EFFECT OF MAGNETIC FIELD TO POSITRON RANGE TO INCREASE SPATIAL RESOLUTION IN POSITRON EMISSION TOMOGRAPHY (PET) IMAGING
title_sort effect of magnetic field to positron range to increase spatial resolution in positron emission tomography (pet) imaging
url https://digilib.itb.ac.id/gdl/view/31820
_version_ 1821996187240103936