ANALYSIS OF GROUND WATER CONTAMINATION BY LEACHATE AROUND AIR DINGIN LANDFILL PADANG
Air dingin landfills in Padang city operations using Open dumping system. There are residents in a radius of 200 m from the landfill that makes the water shallow wells as the main source of water and need to be modeled using the model of Domenico and Scwartz to determine the extent of the spread...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/32110 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | Air dingin landfills in Padang city operations using Open dumping system. There
are residents in a radius of 200 m from the landfill that makes the water shallow
wells as the main source of water and need to be modeled using the model of
Domenico and Scwartz to determine the extent of the spread of leachate on
groundwater. The parameters in the simulation include the Chemical Oxygen
Demand (COD), Lead (Pb) and iron (Fe). From the measurement results of
landfill leachate exceeded the quality standard of Kep. No.. 51/MENLH/I0/1995
Fe 5.4 mg / L, Pb 0.185 mg / L and COD 3400 mg / L. The measurements of
contaminants in the wells is done at a distance of 3 wells with 300, 600 and 900
meters from the landfill in the direction of groundwater flow. The results of
measurements of parameters in wells showed high value of COD. The simulation
of Fe have spread ± 150 m and Pb spread ± 250 m from the landfill following the
groundwater flow. The spread of contaminants COD reaches ± 25 m longitudinal
direction and ± 200 m transversal direction. The pollution prediction of Fe and Pb
in groundwater will be occur in 52 years ahead and reach 312 meters from the
landfill. While the COD concentration through a steady state phrase at 25 meters
from landfill. The increasing of the contaminants COD values measured in wells
around the landfill around Air Dingin Padang not caused by pollution of landfill
leachate, but due to other factors such as high COD content in the groundwater
around landfill sites. |
---|