Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle
One type of weirmeter is weirmeter type V-Notch. Weirmeter is one of the instrument to measure the discharge of an open flow. The flow rate is measured based on the height of the water that passes through weirmeter. Accuracy calculation of flow rates measured by weirmeter influenced by crest width...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Online Access: | https://digilib.itb.ac.id/gdl/view/33826 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:33826 |
---|---|
spelling |
id-itb.:338262019-01-30T10:50:32ZAnalysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle Agung Setiawan, Tommy Indonesia Final Project Value of Cd closest to literature is 0.62 at 22.3 cm of depth and 1 cm of crest width. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/33826 One type of weirmeter is weirmeter type V-Notch. Weirmeter is one of the instrument to measure the discharge of an open flow. The flow rate is measured based on the height of the water that passes through weirmeter. Accuracy calculation of flow rates measured by weirmeter influenced by crest width and height of weirmeter. The crest width and height will affect the value of the discharge coefficient (Cd) of weirmeter. Value of Cd is obtained from weir test with variation of crest width at fixed depth and depth variation at fixed crest width. The experiments were performed at different flow rate. The results of the data processing is the graph of Cd value for all tests. Graph Cd then compared to the literature. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
description |
One type of weirmeter is weirmeter type V-Notch. Weirmeter is one of the instrument to measure the discharge of an open flow. The flow rate is measured based on the height of the water that passes through weirmeter. Accuracy calculation of flow rates measured by weirmeter influenced by crest width and height of weirmeter. The crest width and height will affect the value of the discharge coefficient (Cd) of weirmeter.
Value of Cd is obtained from weir test with variation of crest width at fixed depth and depth variation at fixed crest width. The experiments were performed at different flow rate. The results of the data processing is the graph of Cd value for all tests. Graph Cd then compared to the literature.
|
format |
Final Project |
author |
Agung Setiawan, Tommy |
spellingShingle |
Agung Setiawan, Tommy Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
author_facet |
Agung Setiawan, Tommy |
author_sort |
Agung Setiawan, Tommy |
title |
Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
title_short |
Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
title_full |
Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
title_fullStr |
Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
title_full_unstemmed |
Analysis of Laboratory Testing The Effect of Crest Width and Depth at V-NotchType of Wiremeter With 900 of Angle |
title_sort |
analysis of laboratory testing the effect of crest width and depth at v-notchtype of wiremeter with 900 of angle |
url |
https://digilib.itb.ac.id/gdl/view/33826 |
_version_ |
1822924101868584960 |