MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID

Uric acid is the final product of purine metabolism in human body. Determination of uric acid in human urine is clinically important because abnormality indicates several diseases such as cardiovascular disease, hyperuricemia, gout and Lesch- Nyhan. Determination of uric acid can be done using sever...

Full description

Saved in:
Bibliographic Details
Main Author: Defi Okzelia, Sari
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/34113
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:34113
spelling id-itb.:341132019-02-04T11:03:59ZMOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID Defi Okzelia, Sari Kimia Indonesia Theses Uric acid, poly(methyl red), MIP, voltammetry INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/34113 Uric acid is the final product of purine metabolism in human body. Determination of uric acid in human urine is clinically important because abnormality indicates several diseases such as cardiovascular disease, hyperuricemia, gout and Lesch- Nyhan. Determination of uric acid can be done using several analytical methods such as spectrophotometry, chromatography, capillary electrophoresis and voltammetry.Voltammetry method has many advantages in term of equipment, simplicity of analytical procedures, sensitivity, selectivity and measurement cost. The purpose of this research was to develop voltammetry method for uric acid determination using Molecularly Imprinted Polymer (MIP) modified carbon paste electrode (CPE). The CPE was modifiedwith cyclic voltammetry (CV) technique (15 cycle) at potential range of -1,0 V – 2,0 V and scan rate of 100 mV/s, in solution containing methyl red, uric acid and 0,1 M NaOH as supporting electrolyte. Uric acid was removed using 3 cycles of CV in 0,1 M NaOH at potential range of -0,2 V – 0,8 V and scan rate of 100 mV/s. Uric acid measurements were conducted using square wave voltammetry (SWV) technique in 0,1 M phosphate buffer pH 7 as supporting electrolyte. This electrode provides good response toward uric acid measurements with linear range at concentration range of 1 µM – 200 µM and limit of detection of 0,83 µM. Determination of uric acid in urine resulted in percent recovery between 98,67 – 102,84%, which indicates a good accuracy of the method. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Defi Okzelia, Sari
MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
description Uric acid is the final product of purine metabolism in human body. Determination of uric acid in human urine is clinically important because abnormality indicates several diseases such as cardiovascular disease, hyperuricemia, gout and Lesch- Nyhan. Determination of uric acid can be done using several analytical methods such as spectrophotometry, chromatography, capillary electrophoresis and voltammetry.Voltammetry method has many advantages in term of equipment, simplicity of analytical procedures, sensitivity, selectivity and measurement cost. The purpose of this research was to develop voltammetry method for uric acid determination using Molecularly Imprinted Polymer (MIP) modified carbon paste electrode (CPE). The CPE was modifiedwith cyclic voltammetry (CV) technique (15 cycle) at potential range of -1,0 V – 2,0 V and scan rate of 100 mV/s, in solution containing methyl red, uric acid and 0,1 M NaOH as supporting electrolyte. Uric acid was removed using 3 cycles of CV in 0,1 M NaOH at potential range of -0,2 V – 0,8 V and scan rate of 100 mV/s. Uric acid measurements were conducted using square wave voltammetry (SWV) technique in 0,1 M phosphate buffer pH 7 as supporting electrolyte. This electrode provides good response toward uric acid measurements with linear range at concentration range of 1 µM – 200 µM and limit of detection of 0,83 µM. Determination of uric acid in urine resulted in percent recovery between 98,67 – 102,84%, which indicates a good accuracy of the method.
format Theses
author Defi Okzelia, Sari
author_facet Defi Okzelia, Sari
author_sort Defi Okzelia, Sari
title MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
title_short MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
title_full MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
title_fullStr MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
title_full_unstemmed MOLECULARLY IMPRINTED POLY(METHYL RED) MODIFIED CARBON PASTE ELECTRODE FOR VOLTAMMETRIC DETERMINATION OF URIC ACID
title_sort molecularly imprinted poly(methyl red) modified carbon paste electrode for voltammetric determination of uric acid
url https://digilib.itb.ac.id/gdl/view/34113
_version_ 1822924177490837504