ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT

Imaging is a non-invasive method that is used to see the inferior or functional of the human body. Electrical impedance tomography is one kind of imaging method. Electrical impedance tomography is one of the safest methods and costs less than other imaging methods. The electrical impedance tomograp...

Full description

Saved in:
Bibliographic Details
Main Author: Jaka Wimbang W, Muhammad
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/35844
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:35844
spelling id-itb.:358442019-03-04T11:26:29ZELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT Jaka Wimbang W, Muhammad Indonesia Theses velostat , electrical impedance tomography , configuration , injection and measurements , phantom resistor , signal to noise ratio , standard deviation INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/35844 Imaging is a non-invasive method that is used to see the inferior or functional of the human body. Electrical impedance tomography is one kind of imaging method. Electrical impedance tomography is one of the safest methods and costs less than other imaging methods. The electrical impedance tomography method is used to read the difference in conductivity on the tissue. Electrical impedance tomography method can be used on objects that have different conductivity in them. One of the material that has differences in conductivity is velostat. Velostat is a pressure sensor which when pressure applied the resistance drop. In this study discussing the use of velostat as an object detector. The object that is detected is a weighing scale placed in the middle of velostat surface. The data retrieval process starts with injecting a current or voltage source on a pair of electrodes and measures the voltage on all existing electrodes. There are several configurations for the application. The best configuration is produced from adjacent injection, adjacent measurement (ADAD) after the calculation of average of measurement results from 100 voltage data sets. This voltage data consists of homogeneous and inhomogeneous data which is carried out in steady state. Homogeneous and inhomogeneous data is reconstructed using EIDORS software and the results are processed to seek the quality of the image. The processing is done by calculate the signal to noise ratio (SNR) and standard deviation. The biggest SNR is 47.64 dB from the ADAD configuration and the standard deviation ranges from 0-85. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description Imaging is a non-invasive method that is used to see the inferior or functional of the human body. Electrical impedance tomography is one kind of imaging method. Electrical impedance tomography is one of the safest methods and costs less than other imaging methods. The electrical impedance tomography method is used to read the difference in conductivity on the tissue. Electrical impedance tomography method can be used on objects that have different conductivity in them. One of the material that has differences in conductivity is velostat. Velostat is a pressure sensor which when pressure applied the resistance drop. In this study discussing the use of velostat as an object detector. The object that is detected is a weighing scale placed in the middle of velostat surface. The data retrieval process starts with injecting a current or voltage source on a pair of electrodes and measures the voltage on all existing electrodes. There are several configurations for the application. The best configuration is produced from adjacent injection, adjacent measurement (ADAD) after the calculation of average of measurement results from 100 voltage data sets. This voltage data consists of homogeneous and inhomogeneous data which is carried out in steady state. Homogeneous and inhomogeneous data is reconstructed using EIDORS software and the results are processed to seek the quality of the image. The processing is done by calculate the signal to noise ratio (SNR) and standard deviation. The biggest SNR is 47.64 dB from the ADAD configuration and the standard deviation ranges from 0-85.
format Theses
author Jaka Wimbang W, Muhammad
spellingShingle Jaka Wimbang W, Muhammad
ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
author_facet Jaka Wimbang W, Muhammad
author_sort Jaka Wimbang W, Muhammad
title ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
title_short ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
title_full ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
title_fullStr ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
title_full_unstemmed ELECTRICAL IMPEDANCE TOMOGRAPHY WITH VELOSTAT
title_sort electrical impedance tomography with velostat
url https://digilib.itb.ac.id/gdl/view/35844
_version_ 1821997010881871872