Analysis of Testing Velocity Vector Two Dimension Flow Using Direction-Sensing Probes Method with Diameter Tube 4mm
In the actual condition, there is a boundary layer at the surface of the fluid that flows through the pipe, so then make different magnitude and direction velocity of the fluid. The result that gained hopefully could be developed to get a accurately and precisely result and could be applied for...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/39230 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
Summary: | In the actual condition, there is a boundary layer at the surface of the fluid
that flows through the pipe, so then make different magnitude and direction
velocity of the fluid.
The result that gained hopefully could be developed to get a accurately and
precisely result and could be applied for deciding angle of attack at the suction
side of pump.
This experiment using two impact tube’s diameter is 4mm flowed by
incompressible fluid. The data is data obtained pressure difference that happened
between two tubes. The result that obtained from the experiment compared with
theoretically result.
From the experiment obtained that if flow angle tube smaller, than the
result will be more accurate. So like that, with the angle of the tube will affecting
the accuration in experiment. |
---|