COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING

Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of doubl...

Full description

Saved in:
Bibliographic Details
Main Author: Bahana Utama, Bagus
Format: Theses
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/39509
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:39509
spelling id-itb.:395092019-06-26T14:54:19ZCOMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING Bahana Utama, Bagus Teknik sipil Indonesia Theses Isolation system, Double friction pendulum system, Response spectrum, Nonlinear time history analysis. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/39509 Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of double friction pendulum system (DFPS) is one of the new innovations with the aim of disaster mitigation. The purpose of this study is to compare the performance of structure with and without DFPS at maximum earthquake conditions and to study the effect of stiffness variations and friction coefficient variations from DFPS. Five office building models, ten story tall, with dual system structure which is located in Jakarta with medium soil condition. Seven earthquake data were used with nonlinear time history analysis (NLTHA). The parameters to be compared are structural performance such as the top floor acceleration, base shear, story drift, performance level, dissipation energy and maximum deformation of the DFPS text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik sipil
spellingShingle Teknik sipil
Bahana Utama, Bagus
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
description Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of double friction pendulum system (DFPS) is one of the new innovations with the aim of disaster mitigation. The purpose of this study is to compare the performance of structure with and without DFPS at maximum earthquake conditions and to study the effect of stiffness variations and friction coefficient variations from DFPS. Five office building models, ten story tall, with dual system structure which is located in Jakarta with medium soil condition. Seven earthquake data were used with nonlinear time history analysis (NLTHA). The parameters to be compared are structural performance such as the top floor acceleration, base shear, story drift, performance level, dissipation energy and maximum deformation of the DFPS
format Theses
author Bahana Utama, Bagus
author_facet Bahana Utama, Bagus
author_sort Bahana Utama, Bagus
title COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
title_short COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
title_full COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
title_fullStr COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
title_full_unstemmed COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
title_sort comparative study of structure performance with and without base isolation system using double friction pendulum system on reinforced concrete building
url https://digilib.itb.ac.id/gdl/view/39509
_version_ 1821997792699088896