COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING
Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of doubl...
Saved in:
Main Author: | |
---|---|
Format: | Theses |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/39509 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:39509 |
---|---|
spelling |
id-itb.:395092019-06-26T14:54:19ZCOMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING Bahana Utama, Bagus Teknik sipil Indonesia Theses Isolation system, Double friction pendulum system, Response spectrum, Nonlinear time history analysis. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/39509 Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of double friction pendulum system (DFPS) is one of the new innovations with the aim of disaster mitigation. The purpose of this study is to compare the performance of structure with and without DFPS at maximum earthquake conditions and to study the effect of stiffness variations and friction coefficient variations from DFPS. Five office building models, ten story tall, with dual system structure which is located in Jakarta with medium soil condition. Seven earthquake data were used with nonlinear time history analysis (NLTHA). The parameters to be compared are structural performance such as the top floor acceleration, base shear, story drift, performance level, dissipation energy and maximum deformation of the DFPS text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik sipil |
spellingShingle |
Teknik sipil Bahana Utama, Bagus COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
description |
Important buildings such as hospitals, power generator facilities and other important public facilities that must remain operational when an earthquake occurs are one of the consideration for conducting research and development of new alternative methods. Base isolation system with the type of double friction pendulum system (DFPS) is one of the new innovations with the aim of disaster mitigation. The purpose of this study is to compare the performance of structure with and without DFPS at maximum earthquake conditions and to study the effect of stiffness variations and friction coefficient variations from DFPS. Five office building models, ten story tall, with dual system structure which is located in Jakarta with medium soil condition. Seven earthquake data were used with nonlinear time history analysis (NLTHA). The parameters to be compared are structural performance such as the top floor acceleration, base shear, story drift, performance level, dissipation energy and maximum deformation of the DFPS |
format |
Theses |
author |
Bahana Utama, Bagus |
author_facet |
Bahana Utama, Bagus |
author_sort |
Bahana Utama, Bagus |
title |
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
title_short |
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
title_full |
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
title_fullStr |
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
title_full_unstemmed |
COMPARATIVE STUDY OF STRUCTURE PERFORMANCE WITH AND WITHOUT BASE ISOLATION SYSTEM USING DOUBLE FRICTION PENDULUM SYSTEM ON REINFORCED CONCRETE BUILDING |
title_sort |
comparative study of structure performance with and without base isolation system using double friction pendulum system on reinforced concrete building |
url |
https://digilib.itb.ac.id/gdl/view/39509 |
_version_ |
1821997792699088896 |