ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING

The LFM ITB building, which was built in 1939, continues to function as a supporting facility for educational activities. The building, which was established for approximately 79 years, has changed in the size and shape of building structures and materials. To prevent losses caused by these changes,...

Full description

Saved in:
Bibliographic Details
Main Author: Rifqi Hawaari, Taufiiqulhakim
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/39781
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:39781
spelling id-itb.:397812019-06-27T15:44:39ZANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING Rifqi Hawaari, Taufiiqulhakim Teknik (Rekayasa, enjinering dan kegiatan berkaitan) Indonesia Final Project Terrestrial Laser Scanner, three dimensions, registration, as-built drawing INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/39781 The LFM ITB building, which was built in 1939, continues to function as a supporting facility for educational activities. The building, which was established for approximately 79 years, has changed in the size and shape of building structures and materials. To prevent losses caused by these changes, the LFM Building needs to be renovated in some or all parts of the building without removing the existing characteristics and philosophical values. Therefore, renovations must refer to the building's as-built drawing documents. As-built drawings can be made using terrestrial laser scanner technology. TLS technology will be the main component in making the three-dimensional model of the LFM Building which will later become a reference in making as-built drawings. The analysis in this study is in the form of making as-built and what parts can be reached by TLS. In this research, Building LFM modeling uses data from measurements using TLS. Data is processed through a registration process to unify all data. The average value of registration errors is 0.006 meters. The noise removal process removes unused data. The modeling process is carried out to produce a solid model that represents the shape of the LFM Building in the field. The results of the three-dimensional model will be used as a reference in making as-built drawings that include floor plans, visualizations, and building pieces. The results of the registration are then validated by using a distometer for vertical distance and measuring tape for horizontal distance. Vertical distance validation has the largest value of 0.012 meters and horizontal distance has the largest value of 0.011 meters. The final results of this research are three-dimensional models and an as-built drawing of the LFM ITB Building. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
spellingShingle Teknik (Rekayasa, enjinering dan kegiatan berkaitan)
Rifqi Hawaari, Taufiiqulhakim
ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
description The LFM ITB building, which was built in 1939, continues to function as a supporting facility for educational activities. The building, which was established for approximately 79 years, has changed in the size and shape of building structures and materials. To prevent losses caused by these changes, the LFM Building needs to be renovated in some or all parts of the building without removing the existing characteristics and philosophical values. Therefore, renovations must refer to the building's as-built drawing documents. As-built drawings can be made using terrestrial laser scanner technology. TLS technology will be the main component in making the three-dimensional model of the LFM Building which will later become a reference in making as-built drawings. The analysis in this study is in the form of making as-built and what parts can be reached by TLS. In this research, Building LFM modeling uses data from measurements using TLS. Data is processed through a registration process to unify all data. The average value of registration errors is 0.006 meters. The noise removal process removes unused data. The modeling process is carried out to produce a solid model that represents the shape of the LFM Building in the field. The results of the three-dimensional model will be used as a reference in making as-built drawings that include floor plans, visualizations, and building pieces. The results of the registration are then validated by using a distometer for vertical distance and measuring tape for horizontal distance. Vertical distance validation has the largest value of 0.012 meters and horizontal distance has the largest value of 0.011 meters. The final results of this research are three-dimensional models and an as-built drawing of the LFM ITB Building.
format Final Project
author Rifqi Hawaari, Taufiiqulhakim
author_facet Rifqi Hawaari, Taufiiqulhakim
author_sort Rifqi Hawaari, Taufiiqulhakim
title ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
title_short ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
title_full ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
title_fullStr ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
title_full_unstemmed ANALISIS PEMBUATAN AS BUILT DRAWING GEDUNG LFM ITB MENGGUNAKAN DATA TERESTRIAL LASER SCANNING
title_sort analisis pembuatan as built drawing gedung lfm itb menggunakan data terestrial laser scanning
url https://digilib.itb.ac.id/gdl/view/39781
_version_ 1822925400900108288