Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System

The renewable technology has significantly improved over the last 20 years, especially for Photovoltaics (PV), Nowadays, electricity costs from renewable power generation have continued to fall. After years of steady cost decline, renewable power technologies are becoming an increasingly competit...

Full description

Saved in:
Bibliographic Details
Main Author: Winarko, Tatok
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/39807
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:39807
spelling id-itb.:398072019-06-28T07:58:19ZCost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System Winarko, Tatok Indonesia Theses Cost-Benefit Analysis, Frequency stability, LCOE, PV Penetration INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/39807 The renewable technology has significantly improved over the last 20 years, especially for Photovoltaics (PV), Nowadays, electricity costs from renewable power generation have continued to fall. After years of steady cost decline, renewable power technologies are becoming an increasingly competitive way comparing with fosil-fuel power plants. Indonesia state electric company (PLN) through the Electricity Business plan (RUPTL) 2018-2027 is targeted to realize 23% of energy mix on the renewable energy system. Photovoltaic (PV) is one of the alternative solutions considered due to its environmentally friendly energy and the trend of its price decline. However, PV penetration on the grid may affect the grid frequency stability due to their intermittency. Hence, in this Thesis, the cost-benefit analysis was conducted to calculate the amount of the PV penetration, and then, its impact on frequency stability is analyzed. The South-Central Kalimantan system is used as the study case. The simulations show that PV penetration reduced the NPC (Net Present Cost) and LCOE (Levelized Cost of Energy) of the system. Also, the system frequency deviation was affected by the size of the system load and PV capacity. To maintain the frequency according to the grid code of 49.5 Hz, the use of the battery is required in several scenarios. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The renewable technology has significantly improved over the last 20 years, especially for Photovoltaics (PV), Nowadays, electricity costs from renewable power generation have continued to fall. After years of steady cost decline, renewable power technologies are becoming an increasingly competitive way comparing with fosil-fuel power plants. Indonesia state electric company (PLN) through the Electricity Business plan (RUPTL) 2018-2027 is targeted to realize 23% of energy mix on the renewable energy system. Photovoltaic (PV) is one of the alternative solutions considered due to its environmentally friendly energy and the trend of its price decline. However, PV penetration on the grid may affect the grid frequency stability due to their intermittency. Hence, in this Thesis, the cost-benefit analysis was conducted to calculate the amount of the PV penetration, and then, its impact on frequency stability is analyzed. The South-Central Kalimantan system is used as the study case. The simulations show that PV penetration reduced the NPC (Net Present Cost) and LCOE (Levelized Cost of Energy) of the system. Also, the system frequency deviation was affected by the size of the system load and PV capacity. To maintain the frequency according to the grid code of 49.5 Hz, the use of the battery is required in several scenarios.
format Theses
author Winarko, Tatok
spellingShingle Winarko, Tatok
Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
author_facet Winarko, Tatok
author_sort Winarko, Tatok
title Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
title_short Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
title_full Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
title_fullStr Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
title_full_unstemmed Cost-Benefit Analysis of PV Penetration and Its Impact on the Frequency Stability: Case Study of The South-Central Kalimantan System
title_sort cost-benefit analysis of pv penetration and its impact on the frequency stability: case study of the south-central kalimantan system
url https://digilib.itb.ac.id/gdl/view/39807
_version_ 1822925410403352576