Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02
Selenium is a heavy metal pollutant in aquatic enviromnent. Selenit is a form of inorganic selenium which is toxic to living things. Therefore, we need a sensitive method, which is able to selectively detect and detennine the concentration of selenit species. In this research, the performance optimi...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/42071 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:42071 |
---|---|
spelling |
id-itb.:420712019-09-13T08:45:01ZCopper Amalgam Working Electrode for Voltammetric Analysis ojSe02 Khelfa Pramesti, Muthia Kimia Indonesia Final Project copper amalgam electrode, selenite, voltarnmetry INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/42071 Selenium is a heavy metal pollutant in aquatic enviromnent. Selenit is a form of inorganic selenium which is toxic to living things. Therefore, we need a sensitive method, which is able to selectively detect and detennine the concentration of selenit species. In this research, the performance optimization to determine the selenit species with a square wave stripping voltammetry technique using copper amalgam woking electrode (CuHg). Validation of this method was perfonned using optimum parameter of deposition potential (Eacc) of -450 mV and time of deposition (tacc) of 800 seconds when detennine selenite with square wave stripping voltammetiy technique. This method has a good precision with the standard deviation value (% RSD) of 4.89%. The linear calibration curve is shown in the range of 0.03-0.1 mM with R2 as 0.988 and range 0. 1-0. 7 mM with R2 as 0.995 and also the detection limit as 9 JlM. The standard selenite was measured with square wave stripping voltanunetiy technique with a recovery percentage as 96.67o/o±2.94. The same solution was tested with AAS with a recovery percentage as 96.35% ± 2.36. The statistical test using t test shows that both of these results do not have significant differences with 95% confidence limits. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Kimia |
spellingShingle |
Kimia Khelfa Pramesti, Muthia Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
description |
Selenium is a heavy metal pollutant in aquatic enviromnent. Selenit is a form of inorganic selenium which is toxic to living things. Therefore, we need a sensitive method, which is able to selectively detect and detennine the concentration of selenit species. In this research, the performance optimization to determine the selenit species with a square wave stripping voltammetry technique using copper amalgam woking electrode (CuHg). Validation of this method was perfonned using optimum parameter of deposition potential (Eacc) of -450 mV and time of deposition (tacc) of 800 seconds when detennine selenite with square wave stripping voltammetiy technique. This method has a good precision with the standard deviation value (% RSD) of 4.89%. The linear calibration curve is shown in the range of
0.03-0.1 mM with R2 as 0.988 and range 0. 1-0. 7 mM with R2 as 0.995 and also the
detection limit as 9 JlM. The standard selenite was measured with square wave stripping voltanunetiy technique with a recovery percentage as 96.67o/o±2.94. The same solution was tested with AAS with a recovery percentage as 96.35% ± 2.36. The statistical test using t test shows that both of these results do not have significant differences with 95% confidence limits.
|
format |
Final Project |
author |
Khelfa Pramesti, Muthia |
author_facet |
Khelfa Pramesti, Muthia |
author_sort |
Khelfa Pramesti, Muthia |
title |
Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
title_short |
Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
title_full |
Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
title_fullStr |
Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
title_full_unstemmed |
Copper Amalgam Working Electrode for Voltammetric Analysis ojSe02 |
title_sort |
copper amalgam working electrode for voltammetric analysis ojse02 |
url |
https://digilib.itb.ac.id/gdl/view/42071 |
_version_ |
1821998507428413440 |