Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation

High Performance Liquid Chromatography (HPLC) is the most suited analytical method for sugar analysis based on its accuracy, simplicity on sample preparation, and analysis duration compared to any other methods. Silica amine (Si-NH2 ) column is commonly used in HPLC for sugar anal...

Full description

Saved in:
Bibliographic Details
Main Author: Nuzula Ramdhiny, Masytha
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/42154
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:42154
spelling id-itb.:421542019-09-16T11:24:46ZMaking of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation Nuzula Ramdhiny, Masytha Kimia Indonesia Final Project 1-IPLC, column, silica, amine, sugar INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/42154 High Performance Liquid Chromatography (HPLC) is the most suited analytical method for sugar analysis based on its accuracy, simplicity on sample preparation, and analysis duration compared to any other methods. Silica amine (Si-NH2 ) column is commonly used in HPLC for sugar analysis, however, it is considered expensive for a column. In this research, a Si-NH2 column has been made with silica particles with the size of 30-60 micron which is being modified with 2% and 20% (3-Aminopropyl)trimethoxysilane (3-APTMS). The first step in this experiment begin with activating the silica particles using piranha solution made up of H so. an d 1-1 2 0 30% (3: I). The activated silica is then reacted with 3-APTMS for 24 hours in order to obtain Si-NJ-12 particles, and some of the Si-NH 2 particles go through deactivating process with triethylamine. Every step is followed by characterization using FT-IR and at the end SEM analysis is done. According to FT-IR data, Si-NJ-12 particles are successfully made due to new peaks fanned on the spectrum such as peaks from Si-C (800-950 cm- 1 ), C-N (1000-1350 cm- 1 ), dan N-1-1 ( 1550-1650 cm-1 ). Afterwards, Si-NJ-1 particles are loaded to HPLC column with size of 4.6 mm x I 00 mm. Column is being tested upon glucose, maltose, and a mixture of both which are made by three different solvents similar to the eluents used. Eluents used involves water, aceton itrile, and water-acetonitrile (50:50 ). Based on the experiment, Si-NJ-12 made with 2% 3-APTMS (Si -NJ-12 2%) with eluent of water-acetonitrile (50:50 ) gives the best perfonnance where glucose and maltose sample peaks are formed on different retention time with significant peak shapes. According to SEM data obtained, activat ion and attaching primary am ine on si lica surface have been done successfu ll y. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Nuzula Ramdhiny, Masytha
Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
description High Performance Liquid Chromatography (HPLC) is the most suited analytical method for sugar analysis based on its accuracy, simplicity on sample preparation, and analysis duration compared to any other methods. Silica amine (Si-NH2 ) column is commonly used in HPLC for sugar analysis, however, it is considered expensive for a column. In this research, a Si-NH2 column has been made with silica particles with the size of 30-60 micron which is being modified with 2% and 20% (3-Aminopropyl)trimethoxysilane (3-APTMS). The first step in this experiment begin with activating the silica particles using piranha solution made up of H so. an d 1-1 2 0 30% (3: I). The activated silica is then reacted with 3-APTMS for 24 hours in order to obtain Si-NJ-12 particles, and some of the Si-NH 2 particles go through deactivating process with triethylamine. Every step is followed by characterization using FT-IR and at the end SEM analysis is done. According to FT-IR data, Si-NJ-12 particles are successfully made due to new peaks fanned on the spectrum such as peaks from Si-C (800-950 cm- 1 ), C-N (1000-1350 cm- 1 ), dan N-1-1 ( 1550-1650 cm-1 ). Afterwards, Si-NJ-1 particles are loaded to HPLC column with size of 4.6 mm x I 00 mm. Column is being tested upon glucose, maltose, and a mixture of both which are made by three different solvents similar to the eluents used. Eluents used involves water, aceton itrile, and water-acetonitrile (50:50 ). Based on the experiment, Si-NJ-12 made with 2% 3-APTMS (Si -NJ-12 2%) with eluent of water-acetonitrile (50:50 ) gives the best perfonnance where glucose and maltose sample peaks are formed on different retention time with significant peak shapes. According to SEM data obtained, activat ion and attaching primary am ine on si lica surface have been done successfu ll y.
format Final Project
author Nuzula Ramdhiny, Masytha
author_facet Nuzula Ramdhiny, Masytha
author_sort Nuzula Ramdhiny, Masytha
title Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
title_short Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
title_full Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
title_fullStr Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
title_full_unstemmed Making of Particle for High Performance Liquid Chromatography Colmnn from 3-APTMS Modified Silica for Sugar Separation
title_sort making of particle for high performance liquid chromatography colmnn from 3-aptms modified silica for sugar separation
url https://digilib.itb.ac.id/gdl/view/42154
_version_ 1821998532455825408