Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique

Cadmium is one of the heavy metal sources of envirorunental pollutant. The exposure of cadmium at certain amount and certai n tim e period can cause health issues for human, suc h as cancer, kidney disease, digestive disorder, reproductive system disease, etc. In this research, a...

Full description

Saved in:
Bibliographic Details
Main Author: Asilah, Asri
Format: Final Project
Language:Indonesia
Subjects:
Online Access:https://digilib.itb.ac.id/gdl/view/42156
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:42156
spelling id-itb.:421562019-09-16T11:28:53ZAnalysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique Asilah, Asri Kimia Indonesia Final Project cadmium, sil ver-mercury amalgam, stripping differential pulse voltammehy INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/42156 Cadmium is one of the heavy metal sources of envirorunental pollutant. The exposure of cadmium at certain amount and certai n tim e period can cause health issues for human, suc h as cancer, kidney disease, digestive disorder, reproductive system disease, etc. In this research, a method was developed to determine cadmium using voltammehy method. The working electrode used was silver-mercuty amalgam. The deposition process of amalgam forming on silver wire was canied out at -400 m V for 600 seconds. Cadmium measurement was carried out using stripping differential pulse voltammet.y technique with -1100 mV of deposition potential and 180 seconds of deposition time. The amalgam working-electrode has a good repeatability and the linear regions of 1 - 10 ppb, 20 - 100 ppb, and 200 - 1000 ppb can detect cadmium up to 1.05 ppb. The result of cadmium content in the soil using Stripping DPV was 65,29 ± 1,29 mg/kg with 97,82% recovery. The performance test of the analytical method was caiTied out by comparing the result with the measurement result using AAS method. The result of the petformance test of the analysis method using t-test shows that both of these results from tv.ro different methods do not have any significant difference at 95% confidence level. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
topic Kimia
spellingShingle Kimia
Asilah, Asri
Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
description Cadmium is one of the heavy metal sources of envirorunental pollutant. The exposure of cadmium at certain amount and certai n tim e period can cause health issues for human, suc h as cancer, kidney disease, digestive disorder, reproductive system disease, etc. In this research, a method was developed to determine cadmium using voltammehy method. The working electrode used was silver-mercuty amalgam. The deposition process of amalgam forming on silver wire was canied out at -400 m V for 600 seconds. Cadmium measurement was carried out using stripping differential pulse voltammet.y technique with -1100 mV of deposition potential and 180 seconds of deposition time. The amalgam working-electrode has a good repeatability and the linear regions of 1 - 10 ppb, 20 - 100 ppb, and 200 - 1000 ppb can detect cadmium up to 1.05 ppb. The result of cadmium content in the soil using Stripping DPV was 65,29 ± 1,29 mg/kg with 97,82% recovery. The performance test of the analytical method was caiTied out by comparing the result with the measurement result using AAS method. The result of the petformance test of the analysis method using t-test shows that both of these results from tv.ro different methods do not have any significant difference at 95% confidence level.
format Final Project
author Asilah, Asri
author_facet Asilah, Asri
author_sort Asilah, Asri
title Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
title_short Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
title_full Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
title_fullStr Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
title_full_unstemmed Analysis of Cadmium Content in The Soil Using Silver­ Mercury Amalgam Electrode with Stripping Differential Pulse Anodic Voltammetry Technique
title_sort analysis of cadmium content in the soil using silverâ­ mercury amalgam electrode with stripping differential pulse anodic voltammetry technique
url https://digilib.itb.ac.id/gdl/view/42156
_version_ 1822926189370540032