ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018

The Collapse of Palu IV Bridge during the 28th September 2018 Central Sulawesi earthquake was one of the highlight events for representing the destructive effect of a 7.4 magnitude earthquake that was followed by a tsunami. So far, the causes of bridge collapse have been limited to hypotheses bas...

Full description

Saved in:
Bibliographic Details
Main Author: Habib Supriadi, Ginanjar
Format: Theses
Language:Indonesia
Online Access:https://digilib.itb.ac.id/gdl/view/42501
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Institut Teknologi Bandung
Language: Indonesia
id id-itb.:42501
spelling id-itb.:425012019-09-20T10:07:58ZANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018 Habib Supriadi, Ginanjar Indonesia Theses The Collapse of Palu IV Bridge, 2018 Palu Earthquake, Non-Linear Pushover Analysis. INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/42501 The Collapse of Palu IV Bridge during the 28th September 2018 Central Sulawesi earthquake was one of the highlight events for representing the destructive effect of a 7.4 magnitude earthquake that was followed by a tsunami. So far, the causes of bridge collapse have been limited to hypotheses based on field observation. There are several theories regarding the collapse of the Palu IV Bridge such as failure of bearings due to the large demand of base shear, buckling in the arch ribs or the failure of the main girder. In this study, the bridge will be modeled on a full scale using finite element software Midas Civil. First, the bridge will be checked using the same codes as the original design to acquire the model that represents the real condition of the bridge. Next, the bridge will be checked with the most recent codes to determine the bridge’s condition before the earthquake. All locations where possible failures occurred will also be checked such as bearing failure, buckling on the arch ribs and also a failure on the tie beam. Finally, Non-Linear Static Pushover Analysis will be carried out to obtain the displacement capacity of the bridge, the sequence of plastic hinges formation and the performance level of the bridge. The results of the elastic linear analysis indicated that the main failure occurred in the connection between the superstructure and substructure, where both the anchor bolts and the bearings capacity were not able to withstand the shear forces due to the earthquake load. Meanwhile, pushover analysis shows that the performance of superstructure elements are at the level of fully operational for the longitudinal direction of the bridge and operational for the transverse direction. In pushover analysis, the bearing’s anchor bolts are assumed to have sufficient capacity to withstand shear force from earthquake load. text
institution Institut Teknologi Bandung
building Institut Teknologi Bandung Library
continent Asia
country Indonesia
Indonesia
content_provider Institut Teknologi Bandung
collection Digital ITB
language Indonesia
description The Collapse of Palu IV Bridge during the 28th September 2018 Central Sulawesi earthquake was one of the highlight events for representing the destructive effect of a 7.4 magnitude earthquake that was followed by a tsunami. So far, the causes of bridge collapse have been limited to hypotheses based on field observation. There are several theories regarding the collapse of the Palu IV Bridge such as failure of bearings due to the large demand of base shear, buckling in the arch ribs or the failure of the main girder. In this study, the bridge will be modeled on a full scale using finite element software Midas Civil. First, the bridge will be checked using the same codes as the original design to acquire the model that represents the real condition of the bridge. Next, the bridge will be checked with the most recent codes to determine the bridge’s condition before the earthquake. All locations where possible failures occurred will also be checked such as bearing failure, buckling on the arch ribs and also a failure on the tie beam. Finally, Non-Linear Static Pushover Analysis will be carried out to obtain the displacement capacity of the bridge, the sequence of plastic hinges formation and the performance level of the bridge. The results of the elastic linear analysis indicated that the main failure occurred in the connection between the superstructure and substructure, where both the anchor bolts and the bearings capacity were not able to withstand the shear forces due to the earthquake load. Meanwhile, pushover analysis shows that the performance of superstructure elements are at the level of fully operational for the longitudinal direction of the bridge and operational for the transverse direction. In pushover analysis, the bearing’s anchor bolts are assumed to have sufficient capacity to withstand shear force from earthquake load.
format Theses
author Habib Supriadi, Ginanjar
spellingShingle Habib Supriadi, Ginanjar
ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
author_facet Habib Supriadi, Ginanjar
author_sort Habib Supriadi, Ginanjar
title ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
title_short ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
title_full ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
title_fullStr ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
title_full_unstemmed ANALYSIS OF PALU IV BRIDGE FAILURE DUE TO PALU AND DONGGALA EARTHQUAKE ON 28TH SEPTEMBER 2018
title_sort analysis of palu iv bridge failure due to palu and donggala earthquake on 28th september 2018
url https://digilib.itb.ac.id/gdl/view/42501
_version_ 1822926293902032896