CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING
One of the requirements in the Technical Requirements Guidelines for Buildings by Indonesia Ministry of Public Works is the availability of drinking water supply system in the building and a piping system to dispose of the waste water from the building. The Plumbing system must be able to distribut...
Saved in:
Main Author: | |
---|---|
Format: | Final Project |
Language: | Indonesia |
Subjects: | |
Online Access: | https://digilib.itb.ac.id/gdl/view/42837 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Institut Teknologi Bandung |
Language: | Indonesia |
id |
id-itb.:42837 |
---|---|
spelling |
id-itb.:428372019-09-24T10:37:50ZCLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING Putera Suarjana, Bayu Teknik saniter dan perkotaan; teknik perlindungan lingkungan Indonesia Final Project drinking water, wastewater, rainwater harvesting, hydrant, plumbing, sprinkler INSTITUT TEKNOLOGI BANDUNG https://digilib.itb.ac.id/gdl/view/42837 One of the requirements in the Technical Requirements Guidelines for Buildings by Indonesia Ministry of Public Works is the availability of drinking water supply system in the building and a piping system to dispose of the waste water from the building. The Plumbing system must be able to distribute drinking water to every part of the building is required in the design of a building. Designing drinking water plumbing system can be done in a few steps. Clean water tanks need to be measured first by calculating the water needed by the building before the piping system could be designed. Piping system then can be designed by calculating the number of plumbing instruments and its fixture unit. Similarly, waste water plumbing calculations are also done based on the number of plumbing fixtures and its fixture units. Based on calculation and analysis it can be concluded that the need of water. The used water resources are city water supply, harvested rainwater, and recycled greywater. Treatment of harvested rainwater is conducted first to ensure the water quality based on drinking water quality by The Regulation of Indonesia Ministry of Health. Based on the design of the plumbing system, the pipe diameter of 1 inch and up to 5 inches are used. As part of water supply system and building safety system, fire protection system is also designed. The fire protection system is designed by utilizing hydrant and sprinkler system. text |
institution |
Institut Teknologi Bandung |
building |
Institut Teknologi Bandung Library |
continent |
Asia |
country |
Indonesia Indonesia |
content_provider |
Institut Teknologi Bandung |
collection |
Digital ITB |
language |
Indonesia |
topic |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan |
spellingShingle |
Teknik saniter dan perkotaan; teknik perlindungan lingkungan Putera Suarjana, Bayu CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
description |
One of the requirements in the Technical Requirements Guidelines for Buildings by Indonesia Ministry of Public Works is the availability of drinking water supply system in the building and a piping system to dispose of the waste water from the building. The Plumbing system must be able to distribute drinking water to every part of the building is required in the design of a building. Designing drinking water plumbing system can be done in a few steps. Clean water tanks need to be measured first by calculating the water needed by the building before the piping system could be designed. Piping system then can be designed by calculating the number of plumbing instruments and its fixture unit. Similarly, waste water plumbing calculations are also done based on the number of plumbing fixtures and its fixture units. Based on calculation and analysis it can be concluded that the need of water. The used water resources are city water supply, harvested rainwater, and recycled greywater. Treatment of harvested rainwater is conducted first to ensure the water quality based on drinking water quality by The Regulation of Indonesia Ministry of Health. Based on the design of the plumbing system, the pipe diameter of 1 inch and up to 5 inches are used. As part of water supply system and building safety system, fire protection system is also designed. The fire protection system is designed by utilizing hydrant and sprinkler system.
|
format |
Final Project |
author |
Putera Suarjana, Bayu |
author_facet |
Putera Suarjana, Bayu |
author_sort |
Putera Suarjana, Bayu |
title |
CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
title_short |
CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
title_full |
CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
title_fullStr |
CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
title_full_unstemmed |
CLEAN WATER AND WASTE WATER PLUMBING SYSTEM PLANNING IN THE BANDUNG ARTS AND CULTURE CENTER BUILDING |
title_sort |
clean water and waste water plumbing system planning in the bandung arts and culture center building |
url |
https://digilib.itb.ac.id/gdl/view/42837 |
_version_ |
1821998710707453952 |